Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,969
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0111 # 04 Y:1988 | 04 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $609 | $0 | Not Implemented |
MA0111 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $722 | $2,700 | Not Implemented |
MA0111 # 06 Y:1988 | 06 | 1988 | INSTALL STORM WINDOWS AND DOORS | $1,177 | $2,400 | Implemented |
MA0111 # 07 Y:1988 | 07 | 1988 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $66,605 | $0 | Not Implemented |
MA0111 # 08 Y:1988 | 08 | 1988 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $30,000 | $940 | Implemented |
MA0106 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $334 | $129 | Implemented |
MA0106 # 02 Y:1987 | 02 | 1987 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $429 | $1,250 | Not Implemented |
MA0106 # 03 Y:1987 | 03 | 1987 | REPAIR OR REPLACE STEAM TRAPS | $1,717 | $3,445 | Implemented |
MA0106 # 04 Y:1987 | 04 | 1987 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $2,134 | $5,370 | Not Implemented |
MA0106 # 05 Y:1987 | 05 | 1987 | INSULATE BARE EQUIPMENT | $504 | $1,497 | Not Implemented |
MA0106 # 06 Y:1987 | 06 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $917 | $0 | Implemented |
MA0107 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,770 | $664 | Implemented |
MA0107 # 02 Y:1987 | 02 | 1987 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $132 | $0 | Implemented |
MA0107 # 03 Y:1987 | 03 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,636 | $17,200 | Implemented |
MA0107 # 04 Y:1987 | 04 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $5,097 | $1,800 | Implemented |
MA0107 # 05 Y:1987 | 05 | 1987 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $266 | $100 | Not Implemented |
MA0107 # 06 Y:1987 | 06 | 1987 | INSULATE BARE EQUIPMENT | $167 | $98 | Not Implemented |
MA0109 # 01 Y:1987 | 01 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $346 | $500 | Implemented |
MA0109 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $383 | $87 | Implemented |
MA0109 # 03 Y:1987 | 03 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,845 | $31,000 | Not Implemented |
MA0109 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $122 | $75 | Implemented |
MA0109 # 05 Y:1987 | 05 | 1987 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $626 | $150 | Not Implemented |
MA0110 # 01 Y:1987 | 01 | 1987 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,796 | $7,688 | Not Implemented |
MA0110 # 02 Y:1987 | 02 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,644 | $0 | Not Implemented |
MA0110 # 03 Y:1987 | 03 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $725 | $0 | Not Implemented |