Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0378 # 02 Y:2008 | 02 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,478 | $513 | Not Implemented |
WV0378 # 03 Y:2008 | 03 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,322 | $20 | Not Implemented |
WV0378 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,995 | $2,449 | Implemented |
WV0378 # 05 Y:2008 | 05 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,326 | $0 | Not Implemented |
WV0378 # 06 Y:2008 | 06 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $1,451 | $1,115 | Implemented |
WV0378 # 07 Y:2008 | 07 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,424 | $1,290 | Implemented |
WV0378 # 08 Y:2008 | 08 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $117 | $206 | Implemented |
DL0013 # 01 Y:2008 | 01 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $18,300 | $0 | Implemented |
DL0013 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $2,396 | $285 | Implemented |
DL0013 # 03 Y:2008 | 03 | 2008 | INSULATE BARE EQUIPMENT | $108,300 | $104,800 | Implemented |
DL0013 # 04 Y:2008 | 04 | 2008 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $24,218 | $25,000 | Implemented |
DL0013 # 05 Y:2008 | 05 | 2008 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,700 | $10,000 | Implemented |
LE0272 # 01 Y:2008 | 01 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $130,841 | $80,000 | Not Implemented |
LE0272 # 02 Y:2008 | 02 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $53,138 | $6,600 | Not Implemented |
LE0272 # 03 Y:2008 | 03 | 2008 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $18,111 | $40,000 | Not Implemented |
LE0272 # 04 Y:2008 | 04 | 2008 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $17,652 | $6,200 | Not Implemented |
LE0272 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,361 | $272 | Implemented |
LE0272 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $2,647 | $480 | Not Implemented |
LE0272 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,150 | $92,543 | Not Implemented |
LE0271 # 01 Y:2008 | 01 | 2008 | REPLACE DC EQUIPMENT WITH AC EQUIPMENT | $94,198 | $45,000 | Implemented |
LE0271 # 02 Y:2008 | 02 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $35,042 | $875 | Not Implemented |
LE0271 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,263 | $40,000 | Not Implemented |
LE0271 # 04 Y:2008 | 04 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $17,604 | $3,900 | Not Implemented |
LE0271 # 05 Y:2008 | 05 | 2008 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $14,909 | $30,000 | Not Implemented |
LE0271 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,337 | $3,000 | Implemented |