Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,314
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0184 # 04 Y:1996 | 04 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $21,398 | $25,000 | Implemented |
AS0184 # 05 Y:1996 | 05 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $15,892 | $35,000 | Implemented |
AS0184 # 06 Y:1996 | 06 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,968 | $6,000 | Not Implemented |
AS0184 # 07 Y:1996 | 07 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,569 | $1,500 | Not Implemented |
AS0184 # 08 Y:1996 | 08 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,954 | $4,163 | Implemented |
AS0184 # 09 Y:1996 | 09 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $315 | $0 | Not Implemented |
AS0184 # 10 Y:1996 | 10 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,519 | $2,240 | Not Implemented |
AS0184 # 11 Y:1996 | 11 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,847 | $54,958 | Implemented |
AS0184 # 12 Y:1996 | 12 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $207 | $800 | Not Implemented |
AS0184 # 13 Y:1996 | 13 | 1996 | INSTALL OCCUPANCY SENSORS | $3,057 | $2,475 | Not Implemented |
AS0184 # 14 Y:1996 | 14 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,827 | $1,200 | Implemented |
AS0184 # 15 Y:1996 | 15 | 1996 | TREAT AND REUSE RINSE WATERS | $6,042 | $22,500 | Not Implemented |
AS0183 # 01 Y:1996 | 01 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $14,536 | $7,000 | Not Implemented |
AS0182 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,232 | $0 | Not Implemented |
AS0182 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,782 | $430 | Implemented |
AS0182 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,593 | $500 | Not Implemented |
AS0182 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,259 | $9,718 | Not Implemented |
AS0182 # 05 Y:1996 | 05 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,328 | $21,600 | Not Implemented |
AS0182 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $1,812 | $0 | Not Implemented |
AS0182 # 07 Y:1996 | 07 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,483 | $35,000 | Implemented |
AS0182 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,713 | $10,089 | Not Implemented |
AS0182 # 09 Y:1996 | 09 | 1996 | INSTALL OCCUPANCY SENSORS | $950 | $1,425 | Not Implemented |
AS0182 # 10 Y:1996 | 10 | 1996 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,490 | $1,200 | Implemented |
AS0182 # 11 Y:1996 | 11 | 1996 | MINIMIZE WATER USAGE | $5,511 | $5,000 | Not Implemented |
AS0181 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,027 | $1,500 | Not Implemented |