Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,640
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0008 # 01 Y:2001 | 01 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,300 | $0 | Implemented |
TA0008 # 02 Y:2001 | 02 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,370 | $1,456 | Not Implemented |
TA0008 # 03 Y:2001 | 03 | 2001 | PAY UTILITY BILLS ON TIME | $898 | $0 | Implemented |
TA0008 # 04 Y:2001 | 04 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $664 | $0 | Implemented |
TA0008 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $368 | $634 | Implemented |
TA0008 # 06 Y:2001 | 06 | 2001 | INSTALL OCCUPANCY SENSORS | $260 | $332 | Not Implemented |
SU0112 # 01 Y:2001 | 01 | 2001 | EXPAND OPERATIONS INTO UNUSED SPACE | $3,042 | $30 | Not Implemented |
SU0112 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $319 | $0 | Implemented |
SU0112 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,827 | $2,088 | Implemented |
SU0112 # 04 Y:2001 | 04 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,183 | $90 | Not Implemented |
SU0112 # 05 Y:2001 | 05 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $421 | $0 | Not Implemented |
SU0112 # 06 Y:2001 | 06 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $10,560 | $120,000 | Implemented |
SU0112 # 07 Y:2001 | 07 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $223 | $0 | Not Implemented |
SD0282 # 01 Y:2001 | 01 | 2001 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $2,980,189 | $2,980,189 | Not Implemented |
SD0282 # 02 Y:2001 | 02 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,953 | $190 | Implemented |
SD0282 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $103,026 | $8,000 | Implemented |
SD0282 # 04 Y:2001 | 04 | 2001 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $6,804 | $3,550 | Implemented |
SD0282 # 05 Y:2001 | 05 | 2001 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,312 | $2,000 | Not Implemented |
SD0282 # 06 Y:2001 | 06 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $33,122 | $55,000 | Not Implemented |
SD0282 # 07 Y:2001 | 07 | 2001 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $55,555 | $10,000 | Implemented |
SD0282 # 08 Y:2001 | 08 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $83,687 | $110,000 | Not Implemented |
SD0282 # 09 Y:2001 | 09 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,108 | $8,000 | Not Implemented |
SD0282 # 10 Y:2001 | 10 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $348,473 | $150,000 | Not Implemented |
SD0282 # 11 Y:2001 | 11 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,832,890 | $1,400,000 | Not Implemented |
SD0282 # 12 Y:2001 | 12 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,600 | $500 | Not Implemented |