Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,533
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0212 # 09 Y:2005 | 09 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $230 | $383 | Not Implemented |
SU0212 # 10 Y:2005 | 10 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $148 | $527 | Implemented |
SU0212 # 11 Y:2005 | 11 | 2005 | REDUCE VENTILATION AIR | $3,820 | $13,919 | Not Implemented |
SU0212 # 12 Y:2005 | 12 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $97,661 | $114,600 | Not Implemented |
SU0212 # 13 Y:2005 | 13 | 2005 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $21,189 | $111,859 | Not Implemented |
SD0364 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,817 | $17,315 | Implemented |
SD0364 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,150 | $5,650 | Not Implemented |
SD0364 # 03 Y:2005 | 03 | 2005 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,260 | $6,300 | Implemented |
SD0364 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,016 | $440 | Implemented |
SD0364 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $413 | $400 | Not Implemented |
UF0361 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,815 | $9 | Implemented |
UF0361 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,264 | $1 | Implemented |
UF0361 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,324 | $2 | Implemented |
UF0361 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,002 | $2 | Implemented |
UF0361 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,934 | $0 | Implemented |
UF0361 # 06 Y:2005 | 06 | 2005 | RECYCLE FLUORESCENT LAMPS | $574 | $3 | Not Implemented |
MS0273 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,069 | $12,540 | Not Implemented |
MS0273 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,056 | $26,912 | Not Implemented |
MS0273 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $7,498 | $89 | Implemented |
MS0273 # 04 Y:2005 | 04 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,737 | $685 | Not Implemented |
MS0273 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,326 | $19,601 | Not Implemented |
MS0273 # 06 Y:2005 | 06 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,219 | $1,480 | Not Implemented |
MS0273 # 07 Y:2005 | 07 | 2005 | PAY UTILITY BILLS ON TIME | $3,704 | $0 | Implemented |
MS0273 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,474 | $203 | Not Implemented |
MS0273 # 09 Y:2005 | 09 | 2005 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,353 | $231 | Not Implemented |