Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,032
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0157 # 01 Y:1985 | 01 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $19,738 | $2,752 | Not Implemented |
KU0157 # 02 Y:1985 | 02 | 1985 | IMPROVE LUBRICATION PRACTICES | $1,569 | $290 | Implemented |
KU0152 # 01 Y:1985 | 01 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,790 | $1,100 | Implemented |
KU0152 # 02 Y:1985 | 02 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,286 | $1,500 | Not Implemented |
KU0152 # 03 Y:1985 | 03 | 1985 | USE OPTIMUM TEMPERATURE | $2,973 | $2,000 | Implemented |
KU0152 # 04 Y:1985 | 04 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $2,676 | $149 | Implemented |
KU0152 # 05 Y:1985 | 05 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $859 | $0 | Implemented |
KU0152 # 06 Y:1985 | 06 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,085 | $2,160 | Not Implemented |
KU0152 # 07 Y:1985 | 07 | 1985 | REDUCE VENTILATION AIR | $877 | $100 | Implemented |
KU0152 # 08 Y:1985 | 08 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $176 | $600 | Implemented |
KU0152 # 09 Y:1985 | 09 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $155 | $280 | Implemented |
KU0152 # 10 Y:1985 | 10 | 1985 | INSULATE BARE EQUIPMENT | $129 | $113 | Not Implemented |
KU0152 # 11 Y:1985 | 11 | 1985 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $233 | $14 | Implemented |
KU0152 # 12 Y:1985 | 12 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $189 | $20 | Implemented |
KU0152 # 13 Y:1985 | 13 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $209 | $0 | Implemented |
KU0154 # 01 Y:1985 | 01 | 1985 | IMPROVE LUBRICATION PRACTICES | $18,860 | $0 | Not Implemented |
KU0154 # 02 Y:1985 | 02 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $7,380 | $3,000 | Implemented |
KU0154 # 03 Y:1985 | 03 | 1985 | INSTALL SET-BACK TIMERS | $4,194 | $1,052 | Implemented |
KU0154 # 04 Y:1985 | 04 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,813 | $500 | Implemented |
KU0154 # 05 Y:1985 | 05 | 1985 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $3,686 | $2,700 | Not Implemented |
KU0154 # 06 Y:1985 | 06 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $1,854 | $700 | Not Implemented |
KU0154 # 07 Y:1985 | 07 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $974 | $0 | Implemented |
KU0154 # 08 Y:1985 | 08 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $2,887 | $1,200 | Implemented |
KU0154 # 09 Y:1985 | 09 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $739 | $100 | Not Implemented |
KU0154 # 10 Y:1985 | 10 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $262 | $20 | Not Implemented |