IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,263

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0049 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $360 $100 Implemented
AR0049 # 05 Y:1995 05 1995 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $26,650 $900 Implemented
AR0014 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,666 $871 Implemented
AR0014 # 02 Y:1993 02 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $14,046 $10,310 Implemented
AR0014 # 03 Y:1993 03 1993 USE POWER DURING OFF-PEAK PERIODS $5,562 $3,300 Implemented
AR0014 # 04 Y:1993 04 1993 INSULATE BARE EQUIPMENT $5,187 $2,889 Not Implemented
AR0013 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,017 $586 Implemented
AR0013 # 02 Y:1993 02 1993 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $2,193 $400 Implemented
AR0013 # 03 Y:1993 03 1993 UPGRADE CONVEYORS $31,306 $900 Not Implemented
AR0013 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $12,078 $1,800 Implemented
AR0013 # 05 Y:1993 05 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,521 $8,400 Not Implemented
LT0144 # 01 Y:1989 01 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,927 $0 Implemented
LT0144 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $34 $17 Implemented
LT0144 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $1,494 $0 Implemented
LT0138 # 01 Y:1988 01 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $648 $1,801 Not Implemented
LT0138 # 02 Y:1988 02 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $320 $0 Implemented
LT0138 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $336 $154 Not Implemented
LT0138 # 04 Y:1988 04 1988 INSTALL SET-BACK TIMERS $150 $206 Implemented
LT0140 # 01 Y:1988 01 1988 INSTALL TIMERS AND/OR THERMOSTATS $4,045 $1,350 Implemented
LT0140 # 02 Y:1988 02 1988 RECOVER WASTE HEAT FROM EQUIPMENT $635 $960 Not Implemented
LT0140 # 03 Y:1988 03 1988 INSULATE BARE EQUIPMENT $945 $680 Implemented
LT0140 # 04 Y:1988 04 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $289 $505 Not Implemented
LT0140 # 05 Y:1988 05 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $322 $0 Implemented
LT0140 # 06 Y:1988 06 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $977 $303 Not Implemented
LT0134 # 01 Y:1988 01 1988 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $124 $200 Not Implemented