Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,874
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0250 # 11 Y:1992 | 11 | 1992 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $140 | $240 | Implemented |
CO0250 # 12 Y:1992 | 12 | 1992 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $240 | $1,120 | Implemented |
CO0249 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $630 | $125 | Not Implemented |
CO0249 # 02 Y:1992 | 02 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $370 | $200 | Not Implemented |
CO0249 # 03 Y:1992 | 03 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $260 | $300 | Not Implemented |
CO0249 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,190 | $2,840 | Not Implemented |
CO0249 # 05 Y:1992 | 05 | 1992 | USE POWER DURING OFF-PEAK PERIODS | $960 | $2,000 | Not Implemented |
CO0249 # 06 Y:1992 | 06 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $290 | $450 | Not Implemented |
CO0249 # 07 Y:1992 | 07 | 1992 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,590 | $3,000 | Not Implemented |
CO0249 # 08 Y:1992 | 08 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,390 | $6,430 | Not Implemented |
CO0248 # 01 Y:1992 | 01 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,210 | $350 | Not Implemented |
CO0248 # 02 Y:1992 | 02 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,380 | $4,000 | Not Implemented |
CO0248 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,170 | $730 | Not Implemented |
CO0248 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,750 | $37,860 | Not Implemented |
CO0248 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,800 | $4,760 | Not Implemented |
CO0248 # 06 Y:1992 | 06 | 1992 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $5,460 | $17,470 | Not Implemented |
CO0248 # 07 Y:1992 | 07 | 1992 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $280 | $170 | Not Implemented |
CO0248 # 08 Y:1992 | 08 | 1992 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $400 | $40 | Not Implemented |
CO0247 # 01 Y:1992 | 01 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,020 | $1,250 | Implemented |
CO0247 # 02 Y:1992 | 02 | 1992 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,990 | $1,800 | Implemented |
CO0247 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,480 | $2,560 | Implemented |
CO0247 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,610 | $40 | Implemented |
CO0247 # 05 Y:1992 | 05 | 1992 | INSTALL AUTOMATIC STACK DAMPER | $6,430 | $6,000 | Implemented |
CO0247 # 06 Y:1992 | 06 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,850 | $7,600 | Implemented |
CO0247 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $490 | $780 | Implemented |