IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,533

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0304 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,248 $499 Not Implemented
SF0304 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $465 $588 Not Implemented
SF0304 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $598 $848 Not Implemented
SF0304 # 08 Y:2005 08 2005 INSTALL OCCUPANCY SENSORS $1,062 $1,832 Not Implemented
SF0304 # 09 Y:2005 09 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,442 $19,385 Not Implemented
SF0304 # 10 Y:2005 10 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,879 $12,894 Not Implemented
GT0801 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,040 $32,725 Implemented
GT0801 # 02 Y:2005 02 2005 USE PHOTOCELL CONTROLS $7,520 $32,480 Not Implemented
GT0801 # 03 Y:2005 03 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $72 $0 Implemented
GT0801 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $775 $500 Implemented
GT0801 # 05 Y:2005 05 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $2,820 $500 Not Implemented
GT0801 # 06 Y:2005 06 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,780 $7,500 Not Implemented
GT0801 # 07 Y:2005 07 2005 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $35,100 $15,000 Implemented
GT0801 # 08 Y:2005 08 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $11,320 $10,000 Not Implemented
GT0801 # 09 Y:2005 09 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,950 $6,600 Not Implemented
GT0801 # 10 Y:2005 10 2005 COMBINE UTILITY METERS $12,370 $0 Not Implemented
BD0288 # 01 Y:2005 01 2005 INSTALL REPLACEMENT DOORS $65,227 $72,000 Implemented
BD0288 # 02 Y:2005 02 2005 USE RADIANT HEATER FOR SPOT HEATING $13,106 $12,800 Not Implemented
BD0288 # 03 Y:2005 03 2005 REPLACE BOILER $14,342 $2,500 Implemented
BD0288 # 04 Y:2005 04 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,812 $900 Implemented
BD0288 # 05 Y:2005 05 2005 IMPROVE COMBUSTION CONTROL CAPABILITY $5,194 $2,000 Implemented
BD0288 # 06 Y:2005 06 2005 USE SYNTHETIC LUBRICANT $536 $550 Implemented
BD0288 # 07 Y:2005 07 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,293 $10,160 Implemented
BD0288 # 08 Y:2005 08 2005 REPAIR AND ELIMINATE STEAM LEAKS $2,844 $2,400 Implemented
BD0288 # 09 Y:2005 09 2005 RECOVER WASTE HEAT FROM EQUIPMENT $712 $1,000 Not Implemented