Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,002
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0076 # 03 Y:2012 | 03 | 2012 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $59,645 | $27,000 | Not Implemented |
MZ0076 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $8,058 | $2,310 | Not Implemented |
MZ0076 # 05 Y:2012 | 05 | 2012 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $36,400 | $2,270 | Not Implemented |
OK0825 # 01 Y:2012 | 01 | 2012 | REPLACE BOILER | $228,516 | $1,085,000 | Not Implemented |
OK0825 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,541 | $68,775 | Implemented |
OK0825 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $194 | $3,150 | Not Implemented |
OK0825 # 04 Y:2012 | 04 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $19,699 | $65,000 | Not Implemented |
OK0825 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,478 | $1,500 | Implemented |
OK0825 # 06 Y:2012 | 06 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,119 | $538 | Implemented |
OK0825 # 07 Y:2012 | 07 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,300 | $450 | Not Implemented |
OK0825 # 08 Y:2012 | 08 | 2012 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $62,755 | $31,500 | Not Implemented |
OK0825 # 09 Y:2012 | 09 | 2012 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $15,683 | $15,683 | Not Implemented |
OK0825 # 10 Y:2012 | 10 | 2012 | INSTALL SET-BACK TIMERS | $929 | $937 | Not Implemented |
OK0825 # 11 Y:2012 | 11 | 2012 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,292 | $406,800 | Not Implemented |
OK0825 # 12 Y:2012 | 12 | 2012 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $6,335 | $0 | Not Implemented |
SU0318 # 01 Y:2012 | 01 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,626 | $0 | Not Implemented |
SU0318 # 02 Y:2012 | 02 | 2012 | USE SYNTHETIC LUBRICANT | $7,917 | $0 | Implemented |
SU0318 # 03 Y:2012 | 03 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $72 | $0 | Implemented |
SU0318 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $106,547 | $32,436 | Implemented |
SU0318 # 05 Y:2012 | 05 | 2012 | ELIMINATE/REDUCE AN OPERATION | $12,250 | $11,115 | Not Implemented |
SU0318 # 06 Y:2012 | 06 | 2012 | REDUCE VENTILATION AIR | $3,491 | $4,419 | Not Implemented |
SU0318 # 07 Y:2012 | 07 | 2012 | OPTIMIZE PLANT POWER FACTOR | $162,692 | $408,153 | Implemented |
SU0318 # 08 Y:2012 | 08 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $812 | $3,107 | Not Implemented |
SU0318 # 09 Y:2012 | 09 | 2012 | UPGRADE OBSOLETE EQUIPMENT | $211 | $795 | Implemented |
LE0336 # 01 Y:2012 | 01 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $18,760 | $150 | Implemented |