Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,708
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0420 # 05 Y:2002 | 05 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $993 | $2,094 | Not Implemented |
WI0420 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $576 | $640 | Implemented |
WI0420 # 07 Y:2002 | 07 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $315 | $543 | Implemented |
WI0420 # 08 Y:2002 | 08 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $315 | $0 | Not Implemented |
UF0297 # 01 Y:2002 | 01 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,096 | $7,584 | Implemented |
UF0297 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $21,281 | $33,167 | Implemented |
UF0297 # 03 Y:2002 | 03 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,902 | $0 | Not Implemented |
UF0297 # 04 Y:2002 | 04 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,446 | $2,000 | Implemented |
UF0297 # 05 Y:2002 | 05 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,119 | $1,162 | Not Implemented |
UF0297 # 06 Y:2002 | 06 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $17,690 | $450 | Implemented |
UF0297 # 07 Y:2002 | 07 | 2002 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $64,232 | $59,000 | Not Implemented |
UF0297 # 08 Y:2002 | 08 | 2002 | RECOVER AND REUSE WASTE MATERIAL | $4,950 | $362 | Implemented |
UF0297 # 09 Y:2002 | 09 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $236,669 | $58,500 | Implemented |
UF0297 # 10 Y:2002 | 10 | 2002 | $2,700 | $864 | Not Implemented | |
UF0297 # 11 Y:2002 | 11 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $39,945 | $1,800 | Implemented |
WV0237 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,306 | $1,855 | Implemented |
WV0237 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $946 | $118 | Implemented |
WV0237 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,490 | $470 | Implemented |
WV0237 # 04 Y:2002 | 04 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,170 | $324 | Not Implemented |
WV0237 # 05 Y:2002 | 05 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,375 | $174 | Not Implemented |
WV0237 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,506 | $47 | Implemented |
WV0237 # 07 Y:2002 | 07 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,358 | $100 | Implemented |
WV0237 # 08 Y:2002 | 08 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,569 | $242 | Implemented |
WV0237 # 09 Y:2002 | 09 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $892 | $1,898 | Not Implemented |
WV0237 # 10 Y:2002 | 10 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $10,991 | $297 | Implemented |