Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0247 # 02 Y:2006 | 02 | 2006 | REVISE RAW MATERIAL SPECS | $106,250 | $60,000 | Not Implemented |
LE0247 # 03 Y:2006 | 03 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $26,312 | $16,000 | Not Implemented |
LE0247 # 04 Y:2006 | 04 | 2006 | ADOPT IN-HOUSE MATERIAL GENERATION | $24,012 | $20,000 | Implemented |
LE0247 # 05 Y:2006 | 05 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,245 | $15,000 | Not Implemented |
LE0247 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,646 | $2,500 | Implemented |
LE0247 # 07 Y:2006 | 07 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,225 | $1,152 | Implemented |
LE0247 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $1,181 | $300 | Not Implemented |
LE0247 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,912 | $3,722 | Not Implemented |
WV0350 # 16 Y:2006 | 16 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $438 | $250 | Not Implemented |
WV0350 # 17 Y:2006 | 17 | 2006 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $333 | $0 | Not Implemented |
WV0350 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $44,076 | $2,440 | Implemented |
WV0350 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,663 | $23,600 | Implemented |
WV0350 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,959 | $88,072 | Implemented |
WV0350 # 04 Y:2006 | 04 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,173 | $16,600 | Not Implemented |
WV0350 # 05 Y:2006 | 05 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $14,508 | $2,500 | Implemented |
WV0350 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,094 | $1,000 | Implemented |
WV0350 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,063 | $0 | Implemented |
WV0350 # 08 Y:2006 | 08 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,275 | $60 | Not Implemented |
WV0350 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,103 | $8,181 | Implemented |
WV0350 # 10 Y:2006 | 10 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,679 | $1,000 | Implemented |
WV0350 # 11 Y:2006 | 11 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,824 | $330 | Not Implemented |
WV0350 # 12 Y:2006 | 12 | 2006 | BURN WASTE OIL FOR HEAT | $2,316 | $1,180 | Not Implemented |
WV0350 # 13 Y:2006 | 13 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $1,612 | $735 | Implemented |
WV0350 # 14 Y:2006 | 14 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,174 | $375 | Implemented |
WV0350 # 15 Y:2006 | 15 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $454 | $640 | Not Implemented |