Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,305
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0015 # 04 Y:1991 | 04 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,364 | $8,000 | Implemented |
IA0015 # 05 Y:1991 | 05 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,896 | $5,370 | Implemented |
IA0015 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,851 | $100 | Implemented |
IA0015 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,300 | $4,278 | Implemented |
IA0008 # 01 Y:1991 | 01 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $9,470 | $8,500 | Not Implemented |
IA0008 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,457 | $0 | Not Implemented |
IA0008 # 03 Y:1991 | 03 | 1991 | INSTALL SET-BACK TIMERS | $4,754 | $6,000 | Not Implemented |
IA0008 # 04 Y:1991 | 04 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $293 | $50 | Not Implemented |
IA0008 # 05 Y:1991 | 05 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $237 | $50 | Not Implemented |
IA0009 # 01 Y:1991 | 01 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,612 | $2,000 | Not Implemented |
IA0009 # 02 Y:1991 | 02 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,516 | $250 | Not Implemented |
IA0009 # 03 Y:1991 | 03 | 1991 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $460 | $750 | Not Implemented |
IA0009 # 04 Y:1991 | 04 | 1991 | INSTALL TURBULATORS | $424 | $1,060 | Not Implemented |
IA0009 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $389 | $810 | Not Implemented |
IA0009 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $516 | $0 | Not Implemented |
IA0010 # 01 Y:1991 | 01 | 1991 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $6,926 | $5,950 | Implemented |
IA0010 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,004 | $0 | Implemented |
IA0010 # 03 Y:1991 | 03 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $679 | $2,792 | Implemented |
IA0010 # 04 Y:1991 | 04 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $574 | $450 | Implemented |
IA0012 # 01 Y:1991 | 01 | 1991 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $32,690 | $52,000 | Not Implemented |
IA0012 # 02 Y:1991 | 02 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,436 | $1,120 | Not Implemented |
IA0012 # 03 Y:1991 | 03 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,630 | $6,000 | Not Implemented |
IA0012 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,552 | $0 | Not Implemented |
IA0014 # 01 Y:1991 | 01 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,760 | $1,000 | Not Implemented |
IA0014 # 02 Y:1991 | 02 | 1991 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $787 | $100 | Not Implemented |