Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,315
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0002 # 06 Y:1991 | 06 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $446 | $300 | Implemented |
IA0002 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $141 | $261 | Implemented |
IA0002 # 08 Y:1991 | 08 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $230 | $50 | Implemented |
KU0315 # 01 Y:1990 | 01 | 1990 | RECOVER AND REUSE COOLING WATER | $4,123 | $7,000 | Implemented |
KU0315 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $862 | $100 | Implemented |
KU0315 # 03 Y:1990 | 03 | 1990 | INSTALL SET-BACK TIMERS | $1,130 | $640 | Implemented |
KU0315 # 04 Y:1990 | 04 | 1990 | OPTIMIZE PLANT POWER FACTOR | $518 | $900 | Not Implemented |
KU0315 # 05 Y:1990 | 05 | 1990 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,282 | $100 | Implemented |
KU0316 # 01 Y:1990 | 01 | 1990 | INSTALL SET-BACK TIMERS | $3,487 | $2,075 | Implemented |
KU0316 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $924 | $1,005 | Implemented |
KU0316 # 03 Y:1990 | 03 | 1990 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,122 | $15,000 | Implemented |
KU0316 # 04 Y:1990 | 04 | 1990 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,990 | $7,200 | Not Implemented |
KU0316 # 05 Y:1990 | 05 | 1990 | OPTIMIZE PLANT POWER FACTOR | $2,160 | $2,250 | Implemented |
KU0316 # 06 Y:1990 | 06 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,034 | $1,000 | Implemented |
KU0316 # 07 Y:1990 | 07 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $117 | $0 | Not Implemented |
KU0319 # 01 Y:1990 | 01 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,684 | $2,597 | Not Implemented |
KU0319 # 02 Y:1990 | 02 | 1990 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $6,698 | $1,200 | Implemented |
KU0319 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $604 | $400 | Implemented |
KU0319 # 04 Y:1990 | 04 | 1990 | AIR CONDITION ONLY SPACE NECESSARY | $168 | $400 | Implemented |
KU0319 # 05 Y:1990 | 05 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $360 | Implemented |
KU0319 # 06 Y:1990 | 06 | 1990 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $832 | $487 | Implemented |
KU0319 # 07 Y:1990 | 07 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,125 | $0 | Implemented |
KU0297 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $218 | $119 | Implemented |
KU0297 # 02 Y:1989 | 02 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,367 | $0 | Not Implemented |
KU0297 # 03 Y:1989 | 03 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,843 | $3,200 | Not Implemented |