Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,055

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0564 # 08 Y:1995 08 1995 USE OPTIMUM TEMPERATURE $597 $0 Not Implemented
TN0564 # 09 Y:1995 09 1995 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $77,516 $0 Not Implemented
TN0564 # 10 Y:1995 10 1995 RECYCLE WHITE WATER $32,232 $31,600 Not Implemented
TN0564 # 11 Y:1995 11 1995 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $25,642 $38,600 Not Implemented
TN0564 # 12 Y:1995 12 1995 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $9,920 $0 Not Implemented
WI0238 # 01 Y:1995 01 1995 INSTALL EFFICIENT RECTIFIERS $68,726 $81,000 Not Implemented
WI0238 # 02 Y:1995 02 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $13,411 $2,500 Not Implemented
WI0238 # 03 Y:1995 03 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,134 $1,400 Not Implemented
WI0238 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,493 $6,600 Not Implemented
WI0238 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $384 $880 Not Implemented
WI0238 # 06 Y:1995 06 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,441 $180 Not Implemented
HO0107 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,552 $6,151 Implemented
HO0107 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,441 $1,363 Implemented
HO0107 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,318 $1,000 Not Implemented
HO0107 # 04 Y:1995 04 1995 KEEP BOILER TUBES CLEAN $31,212 $2,500 Not Implemented
OK0472 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,844 $19,582 Implemented
OK0472 # 02 Y:1995 02 1995 INSTALL SET-BACK TIMERS $4,881 $775 Implemented
OK0472 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,501 $5,713 Implemented
OK0472 # 04 Y:1995 04 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,180 $0 Not Implemented
OK0472 # 05 Y:1995 05 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,174 $538 Not Implemented
OK0472 # 06 Y:1995 06 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,475 $4,275 Implemented
OK0472 # 07 Y:1995 07 1995 OPTIMIZE PLANT POWER FACTOR $480 $4,180 Not Implemented
ME0163 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,832 $100,681 Not Implemented
ME0163 # 02 Y:1995 02 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,583 $3,140 Not Implemented
ME0163 # 03 Y:1995 03 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $975 $1,640 Not Implemented