Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,640
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0186 # 06 Y:2001 | 06 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,000 | $700 | n/a |
UM0186 # 07 Y:2001 | 07 | 2001 | OPTIMIZE PLANT POWER FACTOR | $1,500 | $2,300 | n/a |
UM0186 # 08 Y:2001 | 08 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $500 | $1,000 | n/a |
WI0394 # 01 Y:2001 | 01 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $32,472 | $1,611 | n/a |
WI0394 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,875 | $34,038 | n/a |
WI0394 # 03 Y:2001 | 03 | 2001 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,800 | $0 | n/a |
WI0394 # 04 Y:2001 | 04 | 2001 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $4,549 | $9,975 | n/a |
WI0394 # 05 Y:2001 | 05 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,778 | $2,000 | n/a |
WI0394 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,579 | $1,280 | n/a |
WI0394 # 07 Y:2001 | 07 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,450 | $1,263 | n/a |
WI0394 # 08 Y:2001 | 08 | 2001 | RECOVER AND REUSE COOLING WATER | $1,183 | $5,250 | n/a |
AM0398 # 01 Y:2001 | 01 | 2001 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $0 | $0 | Implemented |
AM0398 # 02 Y:2001 | 02 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,960 | $345 | Not Implemented |
AM0398 # 03 Y:2001 | 03 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,100 | $3,824 | Not Implemented |
AM0398 # 04 Y:2001 | 04 | 2001 | USE PHOTOCELL CONTROLS | $840 | $0 | Implemented |
AM0398 # 05 Y:2001 | 05 | 2001 | USE SYNTHETIC LUBRICANT | $840 | $0 | Not Implemented |
AM0398 # 06 Y:2001 | 06 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $530 | $200 | Implemented |
AM0398 # 07 Y:2001 | 07 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $310 | $0 | Implemented |
AM0398 # 08 Y:2001 | 08 | 2001 | PAY UTILITY BILLS ON TIME | $295 | $0 | Implemented |
AM0398 # 09 Y:2001 | 09 | 2001 | WASH AND REUSE RAGS ON-SITE | $170 | $0 | Not Implemented |
AM0398 # 10 Y:2001 | 10 | 2001 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $109 | $0 | Implemented |
BD0186 # 01 Y:2001 | 01 | 2001 | USE RADIANT HEATER FOR SPOT HEATING | $4,762 | $8,000 | Not Implemented |
BD0186 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $924 | $1,118 | Not Implemented |
BD0186 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $828 | $0 | Not Implemented |
BD0186 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $454 | $1,000 | Not Implemented |