IAC logo
IAC Assessment: WI0394
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0394
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2001
Principal Product Commercial Newspapers
NAICS n/a
SIC 2711 - Newspapers
Sales $50,000,000-$100,000,000
# of Employees 500
Plant Area (Sq.Ft.) 220,000
Annual Production 51,792,000 Pieces
Production Hrs. Annual 7,072
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $173,197 5,611,928 kWh $0.03
Electricity Demand $123,761 14,151 kW-months/year $8.75
Electricity Fees $23,131 - $ -
Natural Gas $25,686 5,115 MMBtu $5.02
TOTAL ENERGY COSTS $170,690
RECOMMENDED SAVINGS* $56,686 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Disposal Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Water Disposal Solid Waste (non-haz) Personnel Changes
$ kWh $ kW-months/year $ Tgal $ lb $ $
01: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$32,472
Cost:
$1,611
- - - - - - - - $32,472 - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
lb
$32,472
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,875
Cost:
$34,038
$5,789 177,578 $2,086 226 - - - - - - $5,789
177,578
kWh
$2,086
226
kW-months/year
-
-
Tgal
-
-
lb
-
-
$
03: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$4,800
Cost:
-
- - - - - - $4,800 - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
$4,800
-
lb
-
-
$
04: 2.7251 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF Savings:
$4,549
Cost:
$9,975
$2,451 75,176 $2,168 235 $(-70) (-90,000) - - - - $2,451
75,176
kWh
$2,168
235
kW-months/year
$(-70)
(-90,000)
Tgal
-
-
lb
-
-
$
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,778
Cost:
$2,000
$1,474 45,219 $1,304 141 - - - - - - $1,474
45,219
kWh
$1,304
141
kW-months/year
-
-
Tgal
-
-
lb
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,579
Cost:
$1,280
$1,161 35,614 $418 45 - - - - - - $1,161
35,614
kWh
$418
45
kW-months/year
-
-
Tgal
-
-
lb
-
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,450
Cost:
$1,263
$676 20,722 $774 84 - - - - - - $676
20,722
kWh
$774
84
kW-months/year
-
-
Tgal
-
-
lb
-
-
$
08: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$1,183
Cost:
$5,250
$(-1,291) (-39,568) $(-619) (-67) $3,093 3,959,400 - - - - $(-1,291)
(-39,568)
kWh
$(-619)
(-67)
kW-months/year
$3,093
3,959,400
Tgal
-
-
lb
-
-
$
TOTAL RECOMMENDED Savings:
$56,686
Cost:
$55,417
$10,260 314,741 $6,131 664 $3,023 3,869,400 $4,800 - $32,472 - $10,260
314,741
kWh
$6,131
664
kW-months/year
$3,023
3,869,400
Tgal
$4,800
-
lb
$32,472
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
lb
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ lb $ $
Electricity Usage Electricity Demand Water Disposal Solid Waste (non-haz) Personnel Changes Electricity Usage Electricity Demand Water Disposal Solid Waste (non-haz) Personnel Changes