Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,640

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0186 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $448 $1,125 Not Implemented
BD0186 # 06 Y:2001 06 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $205 $700 Not Implemented
BD0186 # 07 Y:2001 07 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $188 $480 Not Implemented
BD0186 # 08 Y:2001 08 2001 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $4,364 $10,000 Not Implemented
BD0186 # 09 Y:2001 09 2001 MINIMIZE WATER USAGE $264 $690 Not Implemented
BD0186 # 10 Y:2001 10 2001 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $106 $300 Not Implemented
LL0107 # 01 Y:2001 01 2001 OPTIMIZE PLANT POWER FACTOR $4,924 $7,874 Not Implemented
LL0107 # 02 Y:2001 02 2001 IMPROVE COMBUSTION CONTROL CAPABILITY $33,119 $18,760 Not Implemented
LL0107 # 03 Y:2001 03 2001 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $16,897 $0 Implemented
LL0107 # 04 Y:2001 04 2001 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $1,407 $0 Implemented
LL0107 # 05 Y:2001 05 2001 RECYCLE WHITE WATER $25,896 $175,000 Implemented
SD0275 # 01 Y:2001 01 2001 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,842 $1,000 Implemented
SD0275 # 02 Y:2001 02 2001 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,972 $700 Not Implemented
SD0275 # 03 Y:2001 03 2001 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,366 $7,000 Not Implemented
SD0275 # 04 Y:2001 04 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,446 $18,000 n/a
SD0275 # 05 Y:2001 05 2001 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $4,210 $0 Implemented
SD0275 # 06 Y:2001 06 2001 INSTALL SKYLIGHTS $34,893 $12,500 Implemented
SD0275 # 07 Y:2001 07 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,523 $1,080 Implemented
SD0275 # 08 Y:2001 08 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,888 $5,400 Not Implemented
SD0275 # 09 Y:2001 09 2001 USE A DIFFERENT OR RECYCLED RAW MATERIAL $45,000 $0 Not Implemented
SD0275 # 10 Y:2001 10 2001 RECOVER AND REUSE WASTE MATERIAL $312,500 $20,000 Not Implemented
SD0275 # 11 Y:2001 11 2001 INSTALL EQUIPMENT TO MOVE PRODUCT $73,440 $1,500 Not Implemented
SD0275 # 12 Y:2001 12 2001 INSTALL AUTOMATIC PACKING EQUIPMENT $144,380 $35,000 Not Implemented
SD0275 # 13 Y:2001 13 2001 AUTOMATE FINISHING PROCESS $41,960 $80,000 Not Implemented
SD0275 # 14 Y:2001 14 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $6,420 $0 Not Implemented