Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1046 # 04 Y:2021 | 04 | 2021 | OPTIMIZE PLANT POWER FACTOR | $2,125 | $8,240 | Not Implemented |
OK1046 # 05 Y:2021 | 05 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,027 | $38,688 | Implemented |
OK1044 # 01 Y:2021 | 01 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,137 | $0 | Not Implemented |
OK1044 # 02 Y:2021 | 02 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,516 | $3,266 | Not Implemented |
OK1044 # 03 Y:2021 | 03 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,702 | $14,800 | Implemented |
OK1044 # 04 Y:2021 | 04 | 2021 | OPTIMIZE PLANT POWER FACTOR | $3,229 | $11,200 | Not Implemented |
OK1042 # 01 Y:2021 | 01 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,084 | $813 | Not Implemented |
OK1042 # 02 Y:2021 | 02 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,703 | $0 | Implemented |
OK1042 # 03 Y:2021 | 03 | 2021 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $178 | $308 | Not Implemented |
OK1042 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $303 | $1,200 | Not Implemented |
OK1039 # 01 Y:2021 | 01 | 2021 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $361 | $570 | Implemented |
OK1039 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $710 | $3,438 | Implemented |
OK1039 # 03 Y:2021 | 03 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $421 | $488 | Implemented |
OK1039 # 04 Y:2021 | 04 | 2021 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,960 | $4,835 | Not Implemented |
OK1040 # 01 Y:2021 | 01 | 2021 | OPTIMIZE PLANT POWER FACTOR | $83,427 | $407,400 | Not Implemented |
OK1040 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,167 | $70,338 | Not Implemented |
OK1040 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,923 | $2,911 | Implemented |
OK1040 # 04 Y:2021 | 04 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,152 | $4,457 | Implemented |
OK1038 # 01 Y:2021 | 01 | 2021 | INSTALL OCCUPANCY SENSORS | $563 | $1,944 | Not Implemented |
OK1038 # 02 Y:2021 | 02 | 2021 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $24,443 | $2,171 | Not Implemented |
OK1038 # 03 Y:2021 | 03 | 2021 | INSTALL TIMERS AND/OR THERMOSTATS | $991 | $0 | Not Implemented |
OK1037 # 01 Y:2021 | 01 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,395 | $2,804 | Implemented |
OK1037 # 02 Y:2021 | 02 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,825 | $0 | Not Implemented |
OK1037 # 03 Y:2021 | 03 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $587 | $955 | Not Implemented |
OK1037 # 04 Y:2021 | 04 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,155 | $4,128 | Implemented |