Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,485
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0485 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,410 | $17,950 | Not Implemented |
OR0728 # 01 Y:2019 | 01 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $29,023 | $34,574 | Not Implemented |
OR0728 # 02 Y:2019 | 02 | 2019 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $29,427 | $34,054 | Not Implemented |
OR0728 # 03 Y:2019 | 03 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,174 | $4,152 | Not Implemented |
OR0728 # 04 Y:2019 | 04 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,008 | $0 | Implemented |
SU0491 # 01 Y:2019 | 01 | 2019 | DISCONNECT BALLASTS | $1,603 | $0 | Not Implemented |
SU0491 # 02 Y:2019 | 02 | 2019 | ELIMINATE/REDUCE AN OPERATION | $4,160 | $940 | Not Implemented |
SU0491 # 03 Y:2019 | 03 | 2019 | REDUCE VENTILATION AIR | $1,938 | $934 | Not Implemented |
SU0491 # 04 Y:2019 | 04 | 2019 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $405 | $542 | Not Implemented |
SU0491 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,086 | $1,842 | Not Implemented |
SU0491 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,429 | $102,442 | Not Implemented |
SU0491 # 07 Y:2019 | 07 | 2019 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $385 | $1,387 | Not Implemented |
WM0146 # 01 Y:2019 | 01 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $14,090 | $69,698 | Not Implemented |
WM0146 # 02 Y:2019 | 02 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,792 | $16,000 | Not Implemented |
WM0146 # 03 Y:2019 | 03 | 2019 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,022 | $6,480 | Not Implemented |
WM0146 # 04 Y:2019 | 04 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,546 | $16,462 | Not Implemented |
WM0146 # 05 Y:2019 | 05 | 2019 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $936 | $1,950 | Not Implemented |
WM0146 # 06 Y:2019 | 06 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $520 | $618 | Not Implemented |
UD1006 # 01 Y:2019 | 01 | 2019 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $44,647 | $16,500 | Implemented |
UD1006 # 02 Y:2019 | 02 | 2019 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $125,929 | $30,000 | Not Implemented |
UD1006 # 03 Y:2019 | 03 | 2019 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $27,201 | $54,202 | Not Implemented |
UD1006 # 04 Y:2019 | 04 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $50,796 | $0 | Not Implemented |
UD1006 # 05 Y:2019 | 05 | 2019 | INSULATE BARE EQUIPMENT | $8,839 | $3,770 | Not Implemented |
UD1006 # 06 Y:2019 | 06 | 2019 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $7,275 | $16,696 | Not Implemented |
WM0145 # 01 Y:2019 | 01 | 2019 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $29,234 | $3,500 | Not Implemented |