Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,474
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0001 # 07 Y:1994 | 07 | 1994 | REPAIR OR REPLACE STEAM TRAPS | $669 | $400 | Not Implemented |
UF0085 # 01 Y:1994 | 01 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,582 | $250 | Not Implemented |
UF0085 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,229 | $511 | Not Implemented |
UF0085 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,004 | $1,899 | Not Implemented |
UF0085 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $2,413 | $832 | Not Implemented |
UF0085 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $893 | $1,260 | Not Implemented |
UF0085 # 06 Y:1994 | 06 | 1994 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,251 | $7,200 | Not Implemented |
UF0085 # 07 Y:1994 | 07 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,781 | $7,200 | Not Implemented |
UF0085 # 08 Y:1994 | 08 | 1994 | REPLACE ELECTRIC REHEAT WITH HEAT PIPES | $760 | $2,400 | Not Implemented |
UF0085 # 09 Y:1994 | 09 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $718 | $400 | Not Implemented |
ME0120 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $25,173 | $80,000 | Implemented |
ME0120 # 02 Y:1994 | 02 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $658 | $200 | Implemented |
ME0120 # 03 Y:1994 | 03 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $263 | $6,000 | Not Implemented |
ME0120 # 04 Y:1994 | 04 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $205 | $400 | Not Implemented |
ME0120 # 05 Y:1994 | 05 | 1994 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $1,905 | $1,500 | Not Implemented |
AS0117 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,724 | $10,910 | Not Implemented |
AS0117 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,456 | $1,092 | Not Implemented |
AS0117 # 03 Y:1994 | 03 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,276 | $0 | Not Implemented |
AS0117 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $616 | $525 | Not Implemented |
AS0117 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $757 | $441 | Implemented |
AS0117 # 06 Y:1994 | 06 | 1994 | USE SYNTHETIC LUBRICANT | $719 | $705 | Not Implemented |
AS0117 # 07 Y:1994 | 07 | 1994 | USE HEAT PUMP FOR SPACE CONDITIONING | $11,679 | $27,500 | Implemented |
AS0117 # 08 Y:1994 | 08 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,152 | $0 | Not Implemented |
AS0117 # 09 Y:1994 | 09 | 1994 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $22,703 | $20,250 | Not Implemented |
OK0433 # 01 Y:1994 | 01 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $24,035 | $0 | Implemented |