Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0459 # 02 Y:1995 | 02 | 1995 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $9,913 | $1,000 | Implemented |
UD0459 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,174 | $2,605 | Not Implemented |
UD0459 # 04 Y:1995 | 04 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $41,743 | $340,000 | Implemented |
UD0459 # 05 Y:1995 | 05 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $545,061 | $4,500,000 | Implemented |
UL0126 # 01 Y:1995 | 01 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $34,745 | $2,000 | Implemented |
UL0126 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,272 | $40 | Not Implemented |
UL0126 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,595 | $40 | Implemented |
UL0126 # 04 Y:1995 | 04 | 1995 | OPTIMIZE PLANT POWER FACTOR | $24,600 | $16,488 | Not Implemented |
WI0236 # 01 Y:1995 | 01 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,542 | $5,000 | Not Implemented |
WI0236 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,456 | $3,534 | Not Implemented |
WI0236 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,879 | $3,537 | Not Implemented |
WI0236 # 04 Y:1995 | 04 | 1995 | INSTALL OCCUPANCY SENSORS | $1,780 | $1,425 | Not Implemented |
WI0236 # 05 Y:1995 | 05 | 1995 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,883 | $0 | Not Implemented |
WI0236 # 06 Y:1995 | 06 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,497 | $0 | Not Implemented |
WI0236 # 07 Y:1995 | 07 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $937 | $845 | Not Implemented |
WI0236 # 08 Y:1995 | 08 | 1995 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,156 | $400 | Not Implemented |
WI0236 # 09 Y:1995 | 09 | 1995 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $537 | $0 | Not Implemented |
WI0236 # 10 Y:1995 | 10 | 1995 | INSULATE BARE EQUIPMENT | $688 | $635 | Not Implemented |
WI0236 # 11 Y:1995 | 11 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $688 | $640 | Not Implemented |
WI0236 # 12 Y:1995 | 12 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $14,900 | $24,000 | Not Implemented |
WI0236 # 13 Y:1995 | 13 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,200 | $0 | Not Implemented |
WI0236 # 14 Y:1995 | 14 | 1995 | COMBINE UTILITY METERS | $1,160 | $1,400 | Not Implemented |
WV0062 # 01 Y:1995 | 01 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $12,196 | $2,330 | Implemented |
WV0062 # 02 Y:1995 | 02 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,611 | $5,068 | Not Implemented |
WV0062 # 03 Y:1995 | 03 | 1995 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $469 | $800 | Implemented |