Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1995 |
Principal Product | Gear Boxes and Open Gear |
NAICS | n/a |
SIC | 3566 - Speed Changers, Drives, And Gears |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 9,000,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $198,080 | 2,806,858 | kWh | $0.07 |
Natural Gas | $67,611 | 20,698 | MMBtu | $3.27 |
TOTAL ENERGY COSTS | $309,441 | |||
RECOMMENDED SAVINGS* | $41,303 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,542 Cost: $5,000 |
- | - | $5,542 | 1,695 | - | - | - | - | - | - |
- - kWh |
$5,542 1,695 MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,456 Cost: $3,534 |
$5,456 | 77,374 | - | - | - | - | - | - | - | - |
$5,456 77,374 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,879 Cost: $3,537 |
$2,879 | 40,739 | - | - | - | - | - | - | - | - |
$2,879 40,739 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,780 Cost: $1,425 |
$1,780 | 25,205 | - | - | - | - | - | - | - | - |
$1,780 25,205 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $1,883 Cost: - |
$1,883 | - | - | - | - | - | - | - | - | - |
$1,883 - kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,497 Cost: - |
$1,497 | 21,102 | - | - | - | - | - | - | - | - |
$1,497 21,102 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $937 Cost: $845 |
$937 | 13,189 | - | - | - | - | - | - | - | - |
$937 13,189 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $1,156 Cost: $400 |
- | - | $1,156 | 353 | - | - | - | - | - | - |
- - kWh |
$1,156 353 MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $537 Cost: - |
- | - | $537 | 164 | - | - | - | - | - | - |
- - kWh |
$537 164 MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $688 Cost: $635 |
$688 | 9,672 | - | - | - | - | - | - | - | - |
$688 9,672 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $688 Cost: $640 |
$688 | 9,672 | - | - | - | - | - | - | - | - |
$688 9,672 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $14,900 Cost: $24,000 |
- | - | - | - | - | - | $14,900 | - | - | - |
- - kWh |
- - MMBtu |
- - Tgal |
$14,900 - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $2,200 Cost: - |
- | - | - | - | - | - | - | - | $2,200 | 450 |
- - kWh |
- - MMBtu |
- - Tgal |
- - gal |
$2,200 450 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.8112 COMBINE UTILITY METERS |
Savings: $1,160 Cost: $1,400 |
- | - | - | - | $1,160 | - | - | - | - | - |
- - kWh |
- - MMBtu |
$1,160 - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $41,303 Cost: $41,416 |
$15,808 | 196,953 | $7,235 | 2,212 | $1,160 | - | $14,900 | - | $2,200 | 450 | $15,808 196,953 kWh |
$7,235 2,212 MMBtu |
$1,160 - Tgal |
$14,900 - gal |
$2,200 450 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) |