IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,996

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0611 # 03 Y:1997 03 1997 DISTILL CONTAMINATED SOLVENTS FOR REUSE $9,975 $9,596 Not Implemented
TN0611 # 04 Y:1997 04 1997 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,330 $3,240 Implemented
TN0611 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $860 $0 Implemented
ND0272 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $98 $74 Implemented
ND0272 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $288 $800 Implemented
ND0272 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $134 $600 Implemented
ND0272 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,755 $500 Implemented
ND0272 # 05 Y:1997 05 1997 RECOVER WASTE HEAT FROM EQUIPMENT $806 $400 Implemented
ND0272 # 06 Y:1997 06 1997 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $153 $133 Implemented
ND0272 # 07 Y:1997 07 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $15,578 $5,195 Implemented
ND0272 # 08 Y:1997 08 1997 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $40,340 $7,000 Implemented
ND0272 # 09 Y:1997 09 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,544 $8,000 Implemented
ME0217 # 01 Y:1997 01 1997 $7,200 $27,375 Not Implemented
ME0217 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,389 $8,204 Implemented
ME0217 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,895 $13,215 Implemented
ME0217 # 04 Y:1997 04 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,941 $3,276 Implemented
ME0217 # 05 Y:1997 05 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,517 $3,844 Implemented
ME0217 # 06 Y:1997 06 1997 INSTALL / REPAIR INSULATION ON STEAM LINES $597 $603 Implemented
ME0217 # 07 Y:1997 07 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $564 $325 Implemented
ME0217 # 08 Y:1997 08 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $144 $0 Implemented
ME0217 # 09 Y:1997 09 1997 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $500 $0 Implemented
ND0276 # 01 Y:1997 01 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,118 $600 n/a
ND0276 # 02 Y:1997 02 1997 RECOVER WASTE HEAT FROM EQUIPMENT $16,897 $10,000 n/a
ND0276 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $670 $1,053 n/a
ND0276 # 04 Y:1997 04 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $5 $17 n/a