Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,043
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0493 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $2,326 | $2,120 | Not Implemented |
IA0493 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,452 | $2,000 | Implemented |
IA0493 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,291 | $105 | Implemented |
IA0493 # 05 Y:2013 | 05 | 2013 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,659 | $3,000 | Not Implemented |
IA0493 # 06 Y:2013 | 06 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $328 | $200 | Not Implemented |
UA0093 # 01 Y:2013 | 01 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,477 | $15,565 | Not Implemented |
UA0093 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,498 | $2,500 | Implemented |
UA0093 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,514 | $1,600 | Not Implemented |
UA0093 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,728 | $0 | Implemented |
UA0093 # 05 Y:2013 | 05 | 2013 | BURN A LESS EXPENSIVE GRADE OF FUEL | $30,129 | $6,665 | Not Implemented |
SU0334 # 01 Y:2013 | 01 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $814 | $0 | Not Implemented |
SU0334 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $799 | $0 | Implemented |
SU0334 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $648 | $0 | Implemented |
SU0334 # 04 Y:2013 | 04 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $555 | $139 | Implemented |
SU0334 # 05 Y:2013 | 05 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $831 | $307 | Implemented |
SU0334 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $464 | $170 | Implemented |
SU0334 # 07 Y:2013 | 07 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $212 | $393 | Implemented |
SU0334 # 08 Y:2013 | 08 | 2013 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $150 | $414 | Not Implemented |
SU0334 # 09 Y:2013 | 09 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,115 | $8,297 | Not Implemented |
SU0334 # 10 Y:2013 | 10 | 2013 | REPLACE BOILER | $945 | $4,440 | Implemented |
SU0334 # 11 Y:2013 | 11 | 2013 | PAY BILLS ON TIME TO AVOID LATE FEES | $450 | $0 | Implemented |
MZ0109 # 01 Y:2013 | 01 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,287 | $11,200 | Not Implemented |
MZ0109 # 02 Y:2013 | 02 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $14,164 | $10,000 | Not Implemented |
MZ0109 # 03 Y:2013 | 03 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $50,867 | $155,000 | Not Implemented |
SD0461 # 01 Y:2013 | 01 | 2013 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $889,050 | $2,250,000 | Implemented |