Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0535 # 06 Y:2022 | 06 | 2022 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $75,870 | $448,000 | Not Implemented |
DL0210 # 01 Y:2022 | 01 | 2022 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $41,792 | $0 | Not Implemented |
DL0210 # 02 Y:2022 | 02 | 2022 | INSTALL SET-BACK TIMERS | $14,339 | $1,650 | Implemented |
DL0210 # 03 Y:2022 | 03 | 2022 | INSTALL SET-BACK TIMERS | $4,951 | $2,500 | Implemented |
DL0210 # 04 Y:2022 | 04 | 2022 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $264,494 | $0 | Not Implemented |
DL0210 # 05 Y:2022 | 05 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $93,984 | $5,553 | Not Implemented |
DL0210 # 06 Y:2022 | 06 | 2022 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $17,648 | $50,000 | Not Implemented |
DL0210 # 07 Y:2022 | 07 | 2022 | REDUCE EXCESSIVE BOILER BLOWDOWN | $17,995 | $0 | Not Implemented |
DL0210 # 08 Y:2022 | 08 | 2022 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $5,443 | $20,000 | Not Implemented |
DL0210 # 09 Y:2022 | 09 | 2022 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $86,400 | $1,000,000 | Not Implemented |
WV0628 # 07 Y:2022 | 07 | 2022 | DEVELOP A REPAIR/REPLACE POLICY | $371 | $1,608 | Implemented |
WV0628 # 06 Y:2022 | 06 | 2022 | UPGRADE CONTROLS ON COMPRESSORS | $1,374 | $6,454 | Not Implemented |
WV0628 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,802 | $3,626 | Implemented |
WV0628 # 04 Y:2022 | 04 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,819 | $15,170 | Not Implemented |
WV0628 # 03 Y:2022 | 03 | 2022 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $8,049 | $1,000 | Implemented |
WV0628 # 02 Y:2022 | 02 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $15,010 | $73,174 | Not Implemented |
WV0628 # 01 Y:2022 | 01 | 2022 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $31,838 | $14,600 | Not Implemented |
LE0533 # 01 Y:2022 | 01 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,161 | $4,100 | Not Implemented |
LE0533 # 02 Y:2022 | 02 | 2022 | USE RADIANT HEATER FOR SPOT HEATING | $3,206 | $3,500 | Not Implemented |
LE0533 # 03 Y:2022 | 03 | 2022 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $21,231 | $50,000 | Not Implemented |
LE0533 # 04 Y:2022 | 04 | 2022 | BURN A LESS EXPENSIVE GRADE OF FUEL | $24,359 | $62,500 | Not Implemented |
LE0533 # 05 Y:2022 | 05 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,998 | $18,621 | Not Implemented |
LE0533 # 06 Y:2022 | 06 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,903 | $6,154 | Not Implemented |
LE0532 # 01 Y:2022 | 01 | 2022 | PAY UTILITY BILLS ON TIME | $1,087 | $0 | Not Implemented |
LE0532 # 02 Y:2022 | 02 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $1,119 | $460 | Not Implemented |