Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0302 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,152 | $939 | Not Implemented |
ND0302 # 04 Y:1998 | 04 | 1998 | INSTALL OCCUPANCY SENSORS | $453 | $1,200 | Not Implemented |
ND0302 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $345 | $80 | Implemented |
ND0302 # 06 Y:1998 | 06 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $315 | $60 | Implemented |
ND0302 # 07 Y:1998 | 07 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $287 | $60 | Not Implemented |
ND0302 # 08 Y:1998 | 08 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $280 | $1,200 | Not Implemented |
ND0302 # 09 Y:1998 | 09 | 1998 | USE OPTIMUM THICKNESS INSULATION | $260 | $398 | Not Implemented |
ND0302 # 10 Y:1998 | 10 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $189 | $0 | Implemented |
ND0302 # 11 Y:1998 | 11 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $123 | $0 | Implemented |
ND0302 # 12 Y:1998 | 12 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34 | $65 | Not Implemented |
MS0108 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,917 | $3,506 | Not Implemented |
MS0108 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $567 | $696 | Not Implemented |
MS0108 # 03 Y:1998 | 03 | 1998 | USE PHOTOCELL CONTROLS | $3,078 | $759 | Not Implemented |
MS0108 # 04 Y:1998 | 04 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,485 | $0 | Implemented |
MS0108 # 05 Y:1998 | 05 | 1998 | INSULATE BARE EQUIPMENT | $3,162 | $8,391 | Not Implemented |
MS0108 # 06 Y:1998 | 06 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $173,662 | $4,130 | Not Implemented |
GT0636 # 01 Y:1998 | 01 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $49,000 | $0 | Not Implemented |
GT0636 # 02 Y:1998 | 02 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,227 | $0 | Not Implemented |
GT0636 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,388 | $150 | Not Implemented |
GT0636 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,129 | $4,740 | Not Implemented |
GT0636 # 05 Y:1998 | 05 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,095 | $0 | Not Implemented |
GT0636 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,075 | $0 | Not Implemented |
GT0636 # 07 Y:1998 | 07 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,950 | $6,500 | Not Implemented |
GT0636 # 08 Y:1998 | 08 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $825,000 | $0 | Not Implemented |
UF0200 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,619 | $5,500 | Not Implemented |