Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,043
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0630 # 07 Y:2013 | 07 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,240 | $350 | Implemented |
AM0630 # 08 Y:2013 | 08 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,500 | $0 | Not Implemented |
AM0630 # 09 Y:2013 | 09 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,175 | $0 | Not Implemented |
AM0630 # 10 Y:2013 | 10 | 2013 | USE SYNTHETIC LUBRICANT | $480 | $0 | Not Implemented |
AM0630 # 11 Y:2013 | 11 | 2013 | REUSE RAGS UNTIL COMPLETELY SOILED | $480 | $0 | Implemented |
WM0018 # 01 Y:2013 | 01 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,891 | $20,000 | Not Implemented |
WM0018 # 02 Y:2013 | 02 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $30,604 | $50,000 | Not Implemented |
WM0018 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,860 | $488 | Not Implemented |
WM0018 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $542 | $2,210 | Not Implemented |
WM0018 # 05 Y:2013 | 05 | 2013 | INSULATE BARE EQUIPMENT | $11,838 | $1,129 | Not Implemented |
WM0018 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $110 | $244 | Not Implemented |
WM0018 # 07 Y:2013 | 07 | 2013 | SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE | $155 | $480 | Not Implemented |
WM0018 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $1,910 | $1,850 | Not Implemented |
WM0018 # 09 Y:2013 | 09 | 2013 | USE SYNTHETIC LUBRICANT | $1,329 | $550 | Not Implemented |
WM0018 # 10 Y:2013 | 10 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $621 | $0 | Not Implemented |
WM0018 # 11 Y:2013 | 11 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,282 | $295 | Not Implemented |
WM0018 # 12 Y:2013 | 12 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,257 | $0 | Not Implemented |
SU0331 # 01 Y:2013 | 01 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $808 | $0 | Implemented |
SU0331 # 02 Y:2013 | 02 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $211 | $0 | Implemented |
SU0331 # 03 Y:2013 | 03 | 2013 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $19 | $0 | Implemented |
SU0331 # 04 Y:2013 | 04 | 2013 | INSTALL SET-BACK TIMERS | $299 | $228 | Implemented |
SU0331 # 05 Y:2013 | 05 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $142 | $299 | Implemented |
SU0331 # 06 Y:2013 | 06 | 2013 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $188 | $384 | Not Implemented |
SF0425 # 01 Y:2013 | 01 | 2013 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $6,713 | $0 | Implemented |
SF0425 # 02 Y:2013 | 02 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,421 | $7,471 | Implemented |