Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,002
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0846 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $601 | $1,000 | Implemented |
UD0846 # 06 Y:2012 | 06 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,109 | $1,000 | Not Implemented |
UD0846 # 07 Y:2012 | 07 | 2012 | INSULATE BARE EQUIPMENT | $249 | $593 | Not Implemented |
UD0846 # 08 Y:2012 | 08 | 2012 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $11,712 | $38,000 | Implemented |
UD0846 # 09 Y:2012 | 09 | 2012 | REDUCE VENTILATION AIR | $5,608 | $9,000 | Not Implemented |
UD0846 # 10 Y:2012 | 10 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,694 | $0 | Not Implemented |
SF0405 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,795 | $1,200 | Implemented |
SF0405 # 02 Y:2012 | 02 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $76,949 | $36,149 | Implemented |
SF0405 # 03 Y:2012 | 03 | 2012 | INCREASE AMOUNT OF CONDENSATE RETURNED | $139,563 | $85,532 | Implemented |
SF0405 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,933 | $21,797 | Not Implemented |
SF0405 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $38,824 | $39,132 | Not Implemented |
SF0405 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,152 | $11,614 | Not Implemented |
SF0405 # 07 Y:2012 | 07 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $52,595 | $93,960 | Not Implemented |
SF0405 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $3,761 | $9,004 | Implemented |
SF0405 # 09 Y:2012 | 09 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $112,997 | $524,700 | Not Implemented |
SF0405 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,215 | $62,332 | Implemented |
SF0405 # 11 Y:2012 | 11 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,005 | $6,397 | Not Implemented |
BD0404 # 01 Y:2012 | 01 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $49,969 | $32,000 | Not Implemented |
BD0404 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,392 | $76,240 | Implemented |
BD0404 # 03 Y:2012 | 03 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,023 | $25,000 | Not Implemented |
BD0404 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $4,130 | $8,000 | Implemented |
BD0404 # 05 Y:2012 | 05 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,137 | $20 | Implemented |
BD0404 # 06 Y:2012 | 06 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,573 | $1,500 | Implemented |
BD0404 # 07 Y:2012 | 07 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $1,669 | $100 | Implemented |
UMS001 # 01 Y:2012 | 01 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $986,100 | $900,000 | Not Implemented |