Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,002
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0072 # 07 Y:2012 | 07 | 2012 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $36,070 | $1,160 | Implemented |
MZ0072 # 08 Y:2012 | 08 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,583 | $0 | Not Implemented |
MZ0072 # 09 Y:2012 | 09 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,875 | $1,120 | Implemented |
MZ0072 # 10 Y:2012 | 10 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $438 | $0 | Implemented |
MZ0072 # 11 Y:2012 | 11 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,058 | $0 | Implemented |
MZ0072 # 12 Y:2012 | 12 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $22,620 | $0 | Implemented |
MZ0072 # 13 Y:2012 | 13 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,046 | $0 | Implemented |
GT0888 # 01 Y:2012 | 01 | 2012 | USE SYNTHETIC LUBRICANT | $32,596 | $0 | Not Implemented |
GT0888 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $100 | $0 | Not Implemented |
GT0888 # 03 Y:2012 | 03 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,563 | $2,250 | Not Implemented |
GT0888 # 04 Y:2012 | 04 | 2012 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $2,915 | $1,680 | Not Implemented |
GT0888 # 05 Y:2012 | 05 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,200 | $15,000 | Not Implemented |
GT0888 # 06 Y:2012 | 06 | 2012 | INSTALL OCCUPANCY SENSORS | $12,520 | $18,060 | Not Implemented |
GT0888 # 07 Y:2012 | 07 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,690 | $109,600 | Not Implemented |
GT0888 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,305 | $18,600 | Not Implemented |
LL0363 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,101 | $1,200 | Implemented |
LL0363 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $954 | $6,400 | Implemented |
LL0363 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $829 | $3,325 | Implemented |
LL0363 # 04 Y:2012 | 04 | 2012 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,323 | $420 | Not Implemented |
LL0363 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $455 | $960 | Not Implemented |
LL0363 # 06 Y:2012 | 06 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $269 | $368 | Not Implemented |
BD0403 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,988 | $5,268 | Implemented |
BD0403 # 02 Y:2012 | 02 | 2012 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,936 | $440 | Not Implemented |
BD0403 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,011 | $150 | Implemented |
BD0403 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $756 | $10 | Implemented |