IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,708

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0028 # 03 Y:2002 03 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,369 $4,933 Not Implemented
IC0028 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,993 $26,387 Not Implemented
IC0028 # 05 Y:2002 05 2002 INSTALL OCCUPANCY SENSORS $746 $1,370 Not Implemented
IC0028 # 06 Y:2002 06 2002 MODIFY WORKLOAD $29,190 $29,765 Not Implemented
UF0290 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,693 $20,165 Not Implemented
UF0290 # 02 Y:2002 02 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $35,297 $71,595 Not Implemented
UF0290 # 03 Y:2002 03 2002 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $864,295 $3,600,000 Not Implemented
UF0290 # 04 Y:2002 04 2002 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $18,405 $33,700 Not Implemented
UF0290 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,807 $0 Not Implemented
UF0290 # 06 Y:2002 06 2002 USE OPTIMUM TEMPERATURE $234,181 $2,080 Not Implemented
UF0290 # 07 Y:2002 07 2002 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $3,259 $1,633 Not Implemented
UF0290 # 08 Y:2002 08 2002 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,947 $2,300 Not Implemented
UF0290 # 09 Y:2002 09 2002 USE TANKS WITH A CONICAL BOTTOM OUTLET SECTION TO REDUCE WASTE ASSOCIATED WITH THE INTERFACE OF TWO LIQUIDS $17,094 $0 Not Implemented
UF0290 # 10 Y:2002 10 2002 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $174,200 $0 Not Implemented
UF0290 # 11 Y:2002 11 2002 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT $138,643 $29,000 Not Implemented
LM0027 # 01 Y:2002 01 2002 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $16,547 $0 Not Implemented
LM0027 # 02 Y:2002 02 2002 DISCONNECT BALLASTS $199 $200 Not Implemented
LM0027 # 03 Y:2002 03 2002 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $12,600 $1,000 Implemented
LM0027 # 04 Y:2002 04 2002 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE $100,000 $28,080 Not Implemented
LM0027 # 05 Y:2002 05 2002 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $2,362 $520 Not Implemented
AS0318 # 01 Y:2002 01 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $4,443 $600 Implemented
AS0318 # 02 Y:2002 02 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,055 $2,106 Implemented
AS0318 # 03 Y:2002 03 2002 INSTALL OCCUPANCY SENSORS $155 $600 Implemented
AS0318 # 04 Y:2002 04 2002 USE PLASTIC PALLETS INSTEAD OF WOOD $147,420 $166,600 Implemented
AS0318 # 05 Y:2002 05 2002 MINIMIZE WATER USAGE $6,973 $720 Implemented