Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0057 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,861 | $6,766 | Implemented |
BD0057 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,689 | $6,130 | Implemented |
BD0057 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $245 | $300 | Implemented |
BD0057 # 06 Y:1996 | 06 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $1,597 | $750 | Not Implemented |
BD0057 # 07 Y:1996 | 07 | 1996 | RECOVER AND REUSE COOLING WATER | $1,566 | $3,018 | Implemented |
UM0054 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,890 | $10,080 | Not Implemented |
UM0054 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,793 | $16,153 | Not Implemented |
UM0054 # 03 Y:1996 | 03 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,323 | $0 | Not Implemented |
UM0054 # 04 Y:1996 | 04 | 1996 | USE RADIANT HEATER FOR SPOT HEATING | $10,280 | $17,000 | Not Implemented |
UM0054 # 05 Y:1996 | 05 | 1996 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,565 | $0 | Not Implemented |
UM0054 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $2,040 | $3,000 | Not Implemented |
OK0493 # 01 Y:1996 | 01 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $92 | $100 | Implemented |
OK0493 # 02 Y:1996 | 02 | 1996 | USE PHOTOCELL CONTROLS | $237 | $90 | Not Implemented |
OK0493 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,380 | $1,416 | Implemented |
OK0493 # 04 Y:1996 | 04 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,474 | $277 | Not Implemented |
OK0493 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $143 | $321 | Implemented |
OK0493 # 06 Y:1996 | 06 | 1996 | RECYCLE CLEANING SOLVENT AND REUSE | $6,123 | $500 | Not Implemented |
OK0493 # 07 Y:1996 | 07 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $64 | $60 | Implemented |
OK0493 # 08 Y:1996 | 08 | 1996 | INSTALL OCCUPANCY SENSORS | $113 | $336 | Not Implemented |
OK0495 # 01 Y:1996 | 01 | 1996 | INSTALL SET-BACK TIMERS | $5,943 | $1,050 | Implemented |
OK0495 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $66 | $228 | Not Implemented |
OK0495 # 03 Y:1996 | 03 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $854 | $65 | Not Implemented |
OK0495 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $104 | $132 | Not Implemented |
OK0495 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $232 | $244 | Implemented |
OK0495 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $246 | $120 | Implemented |