Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,533
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0216 # 07 Y:2005 | 07 | 2005 | COMBINE UTILITY METERS | $1,025 | $720 | Implemented |
LL0216 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $290 | $300 | Not Implemented |
LL0216 # 09 Y:2005 | 09 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,445 | $0 | Implemented |
LL0216 # 10 Y:2005 | 10 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $13,500 | $2,170 | Not Implemented |
LL0216 # 11 Y:2005 | 11 | 2005 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $12,630 | $18,780 | Not Implemented |
LL0216 # 12 Y:2005 | 12 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,040 | $2,303 | Implemented |
OK0701 # 01 Y:2005 | 01 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $11,182 | $123,420 | Implemented |
OK0701 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,527 | $3,807 | Not Implemented |
OK0701 # 03 Y:2005 | 03 | 2005 | INSULATE BARE EQUIPMENT | $43,354 | $1,623 | Implemented |
OK0701 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,396 | $8,850 | Implemented |
OK0701 # 05 Y:2005 | 05 | 2005 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $19,082 | $13,500 | Not Implemented |
OK0701 # 06 Y:2005 | 06 | 2005 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $4,169 | $275 | Not Implemented |
WI0483 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,449 | $18,810 | n/a |
WI0483 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,950 | $10,000 | Not Implemented |
WI0483 # 03 Y:2005 | 03 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,804 | $500 | Not Implemented |
WI0483 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,164 | $830 | Implemented |
WI0483 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,971 | $2,186 | Not Implemented |
WI0483 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,886 | $0 | Not Implemented |
WI0483 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $393 | $40 | Not Implemented |
LL0215 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,791 | $3,680 | Implemented |
LL0215 # 02 Y:2005 | 02 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $6,317 | $381 | Not Implemented |
LL0215 # 03 Y:2005 | 03 | 2005 | USE PHOTOCELL CONTROLS | $5,700 | $1,530 | Not Implemented |
LL0215 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,452 | $845 | Not Implemented |
LL0215 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $764 | $240 | Not Implemented |
LL0215 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $753 | $240 | Not Implemented |