Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0198 # 06 Y:2000 | 06 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $782 | $416 | Not Implemented |
WV0198 # 07 Y:2000 | 07 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $22,060 | $0 | Implemented |
WV0198 # 08 Y:2000 | 08 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,141 | $23 | Implemented |
WV0198 # 09 Y:2000 | 09 | 2000 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $15,135 | $20,000 | Not Implemented |
WV0198 # 10 Y:2000 | 10 | 2000 | CLEAR AND RENT EXISTING SPACE | $6,000 | $100 | Not Implemented |
WV0198 # 11 Y:2000 | 11 | 2000 | INSTALL SENSORS TO DETECT DEFECTS | $8,580 | $125 | Implemented |
HO0231 # 01 Y:2000 | 01 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,008 | $0 | Implemented |
HO0231 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $2,854 | $5,000 | Implemented |
HO0231 # 03 Y:2000 | 03 | 2000 | INSULATE BARE EQUIPMENT | $5,519 | $9,992 | Implemented |
HO0231 # 04 Y:2000 | 04 | 2000 | INSULATE BARE EQUIPMENT | $3,996 | $5,204 | Not Implemented |
HO0231 # 05 Y:2000 | 05 | 2000 | MOVE BOILER TO MORE EFFICIENT LOCATION | $1,070 | $200 | Not Implemented |
HO0231 # 06 Y:2000 | 06 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,350 | $3,000 | Not Implemented |
HO0231 # 07 Y:2000 | 07 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,373 | $2,790 | Implemented |
HO0231 # 08 Y:2000 | 08 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $398 | $0 | Implemented |
HO0231 # 09 Y:2000 | 09 | 2000 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $85,091 | $4,000 | Not Implemented |
HO0231 # 10 Y:2000 | 10 | 2000 | IMPROVE PROCESS CONTROL TO PREVENT SPILLS OF MATERIAL | $73,575 | $0 | Implemented |
HO0231 # 11 Y:2000 | 11 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $15,600 | $300 | Not Implemented |
HO0231 # 12 Y:2000 | 12 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $15,600 | $3,000 | Implemented |
HO0231 # 13 Y:2000 | 13 | 2000 | INSTALL SYSTEM TO COLLECT SCRAP | $12,375 | $1,075 | Implemented |
HO0231 # 14 Y:2000 | 14 | 2000 | INSTALL CONTINUOUS LUBRICATION EQUIPMENT | $5,850 | $20,000 | Not Implemented |
HO0231 # 15 Y:2000 | 15 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $2,880 | $200 | Not Implemented |
HO0231 # 16 Y:2000 | 16 | 2000 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,980 | $20,017 | Not Implemented |
HO0231 # 17 Y:2000 | 17 | 2000 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $79,092 | $7,100 | Implemented |
HO0231 # 18 Y:2000 | 18 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $7,809 | $2,360 | Implemented |
HO0231 # 19 Y:2000 | 19 | 2000 | TREAT AND REUSE RINSE WATERS | $4,617 | $10,100 | Not Implemented |