Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,304
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0438 # 11 Y:2010 | 11 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $14,482 | $0 | Not Implemented |
UF0438 # 12 Y:2010 | 12 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,717 | $0 | Not Implemented |
UA3006 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,330 | $5,324 | Implemented |
UA3006 # 02 Y:2010 | 02 | 2010 | USE PHOTOCELL CONTROLS | $197 | $112 | Not Implemented |
UA3006 # 03 Y:2010 | 03 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $773 | $170 | Implemented |
UA3006 # 04 Y:2010 | 04 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $316 | $50 | Implemented |
UA3006 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,276 | $800 | Implemented |
UA3006 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,472 | $5,000 | Not Implemented |
UA3006 # 07 Y:2010 | 07 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,594 | $1,550 | Not Implemented |
MZ0055 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,916 | $1,100 | Implemented |
MZ0055 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $770 | $700 | Not Implemented |
MZ0055 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,900 | $1,160 | Implemented |
MZ0055 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,282 | $16,460 | Implemented |
MZ0055 # 05 Y:2010 | 05 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,888 | $0 | Not Implemented |
MZ0055 # 06 Y:2010 | 06 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $0 | $0 | Implemented |
MZ0055 # 07 Y:2010 | 07 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $0 | $0 | Implemented |
UA3005 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $30,246 | $34,285 | Not Implemented |
UA3005 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,085 | $42,861 | Implemented |
UA3005 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,974 | $730 | Not Implemented |
UA3005 # 04 Y:2010 | 04 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $9,502 | $20,000 | Implemented |
UA3005 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,061 | $5,448 | Not Implemented |
UA3005 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,840 | $400 | Not Implemented |
UA3005 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,333 | $1,000 | Not Implemented |
UA3005 # 08 Y:2010 | 08 | 2010 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $122,417 | $2,400 | Implemented |
UA3005 # 09 Y:2010 | 09 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,056 | $2,750 | Not Implemented |