IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,874

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0044 # 03 Y:1985 03 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,668 $100 Implemented
CO0044 # 04 Y:1985 04 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $368 $300 Not Implemented
CO0044 # 05 Y:1985 05 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $128 $200 Not Implemented
CO0044 # 06 Y:1985 06 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,521 $4,257 Not Implemented
CO0044 # 07 Y:1985 07 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $836 $1,714 Not Implemented
CO0044 # 08 Y:1985 08 1985 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $962 $600 Implemented
CO0044 # 09 Y:1985 09 1985 INSTALL TIMERS AND/OR THERMOSTATS $6,495 $122 Implemented
CO0044 # 10 Y:1985 10 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,073 $1,930 Not Implemented
CO0045 # 01 Y:1985 01 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,273 $1,500 Not Implemented
CO0045 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,736 $300 Implemented
CO0045 # 03 Y:1985 03 1985 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,875 $200 Not Implemented
CO0045 # 04 Y:1985 04 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $559 $400 Not Implemented
CO0045 # 05 Y:1985 05 1985 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $440 $300 Implemented
CO0045 # 06 Y:1985 06 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,215 $6,411 Implemented
CO0046 # 01 Y:1985 01 1985 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $5,907 $6,000 Not Implemented
CO0046 # 02 Y:1985 02 1985 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $10,101 $4,825 Not Implemented
CO0046 # 03 Y:1985 03 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,126 $29,000 Not Implemented
CO0046 # 04 Y:1985 04 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,962 $2,990 Not Implemented
CO0046 # 05 Y:1985 05 1985 INSTALL STORM WINDOWS AND DOORS $669 $650 Not Implemented
CO0046 # 06 Y:1985 06 1985 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $977 $1,000 Not Implemented
CO0046 # 07 Y:1985 07 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $489 $150 Not Implemented
CO0046 # 08 Y:1985 08 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,652 $200 Not Implemented
CO0046 # 09 Y:1985 09 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,212 $1,394 Not Implemented
CO0047 # 01 Y:1985 01 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,203 $4,000 Not Implemented
CO0047 # 02 Y:1985 02 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $956 $150 Implemented