Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,055

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0112 # 03 Y:1995 03 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,144 $1,600 Implemented
SD0112 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $2,282 $563 Implemented
SD0112 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,168 $6,733 Implemented
SD0112 # 06 Y:1995 06 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $5,047 $4,305 Implemented
SD0112 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $494 $599 Not Implemented
SD0112 # 08 Y:1995 08 1995 INSTALL TIMERS AND/OR THERMOSTATS $1,306 $849 Implemented
SD0112 # 09 Y:1995 09 1995 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $730 $250 Implemented
SD0112 # 10 Y:1995 10 1995 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $2,184 $0 Not Implemented
SD0112 # 11 Y:1995 11 1995 USE HIGH QUALITY SCRAP (LOW SULFUR) TO REDUCE HAZARDOUS SLUDGE GENERATION $1,069 $1,000 Implemented
ME0155 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,097 $20,385 Implemented
ME0155 # 02 Y:1995 02 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $12,904 $20,000 Implemented
ME0155 # 03 Y:1995 03 1995 CLOSE OFF UNNEEDED STEAM LINES $1,120 $200 Implemented
ME0155 # 04 Y:1995 04 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $952 $350 Implemented
ME0155 # 05 Y:1995 05 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $907 $400 Implemented
ME0155 # 06 Y:1995 06 1995 USE OPTIMUM THICKNESS INSULATION $772 $130 Implemented
CO0328 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,250 $11,610 Implemented
CO0328 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,930 $10,500 Implemented
CO0328 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $2,390 $1,710 Not Implemented
CO0328 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $310 $240 Implemented
GT0551 # 01 Y:1995 01 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $65,795 $0 Implemented
GT0551 # 02 Y:1995 02 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $39,160 $80,000 Not Implemented
GT0551 # 03 Y:1995 03 1995 INSTALL AUTOMATIC STACK DAMPER $50,375 $41,900 Implemented
GT0551 # 04 Y:1995 04 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $34,790 $16,500 Implemented
GT0551 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21,276 $87,727 Implemented
GT0551 # 06 Y:1995 06 1995 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $7,840 $0 Not Implemented