IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,872

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0539 # 03 Y:1998 03 1998 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $39,482 $0 Not Implemented
UD0539 # 04 Y:1998 04 1998 INCREASE AMOUNT OF CONDENSATE RETURNED $8,880 $15,000 Implemented
WV0137 # 01 Y:1998 01 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $554 $440 Implemented
WV0137 # 02 Y:1998 02 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,014 $11,290 Implemented
WV0137 # 03 Y:1998 03 1998 INSULATE BARE EQUIPMENT $500 $290 Implemented
WV0137 # 04 Y:1998 04 1998 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $527 $2,700 Not Implemented
WV0137 # 05 Y:1998 05 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,117 $1,875 Not Implemented
WV0137 # 06 Y:1998 06 1998 INSULATE BARE EQUIPMENT $1,532 $1,120 Implemented
WV0137 # 07 Y:1998 07 1998 RECOVER WASTE HEAT FROM EQUIPMENT $568 $840 Not Implemented
WV0137 # 08 Y:1998 08 1998 RECOVER AND REUSE COOLING WATER $1,307 $1,300 Not Implemented
WV0137 # 09 Y:1998 09 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,975 $11,000 Not Implemented
WV0137 # 10 Y:1998 10 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,512 $0 Implemented
WV0137 # 11 Y:1998 11 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $49,920 $15,000 Implemented
WV0136 # 05 Y:1998 05 1998 RECOVER WASTE HEAT FROM EQUIPMENT $17,164 $2,265 Not Implemented
WV0136 # 06 Y:1998 06 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $9,240 $2,000 Implemented
WV0136 # 07 Y:1998 07 1998 USE SYNTHETIC LUBRICANT $2,115 $2,070 Implemented
WV0136 # 08 Y:1998 08 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $13,347 $11,000 Not Implemented
WV0136 # 09 Y:1998 09 1998 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,625 $1,480 Not Implemented
WV0136 # 10 Y:1998 10 1998 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $9,000 $2,500 Implemented
UL0191 # 01 Y:1998 01 1998 OPTIMIZE PLANT POWER FACTOR $12,699 $13,313 Not Implemented
UL0191 # 02 Y:1998 02 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,913 $0 Not Implemented
UL0191 # 03 Y:1998 03 1998 MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT $390,882 $340,000 Not Implemented
UL0191 # 04 Y:1998 04 1998 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $8,735 $8,500 Not Implemented
UL0191 # 05 Y:1998 05 1998 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $81,500 $15,000 Not Implemented
WV0136 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,626 $10,375 Implemented