Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
125,849
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0108 # 06 Y:2013 | 06 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,603 | $2,591 | Implemented |
UA0108 # 07 Y:2013 | 07 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,872 | $1,425 | Not Implemented |
UA0108 # 08 Y:2013 | 08 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $2,099 | $152 | Implemented |
BD0431 # 01 Y:2013 | 01 | 2013 | USE PHOTOCELL CONTROLS | $1,658 | $1,770 | Not Implemented |
BD0431 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $761 | $2,800 | Implemented |
BD0431 # 03 Y:2013 | 03 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $647 | $220 | Implemented |
BD0431 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $587 | $2,261 | Implemented |
BD0431 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $483 | $295 | Implemented |
BD0431 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $373 | $100 | Implemented |
BD0431 # 07 Y:2013 | 07 | 2013 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $12,000 | $1,000 | Implemented |
WV0474 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,986 | $15,864 | Implemented |
WV0474 # 02 Y:2013 | 02 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,866 | $21,080 | Not Implemented |
WV0474 # 03 Y:2013 | 03 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,698 | $1,000 | Implemented |
WV0474 # 04 Y:2013 | 04 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,360 | $0 | Not Implemented |
WV0474 # 05 Y:2013 | 05 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,920 | $72 | Implemented |
WV0474 # 06 Y:2013 | 06 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $1,715 | $392 | Implemented |
WV0474 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,586 | $324 | Implemented |
WV0474 # 08 Y:2013 | 08 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $967 | $6,150 | Not Implemented |
WV0474 # 09 Y:2013 | 09 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $701 | $960 | Not Implemented |
WV0474 # 10 Y:2013 | 10 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $407 | $500 | Implemented |
DL0112 # 01 Y:2013 | 01 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $48,700 | $2,341 | Not Implemented |
DL0112 # 02 Y:2013 | 02 | 2013 | REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS | $8,930 | $2,820 | Not Implemented |
DL0112 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,900 | $40,000 | Implemented |
DL0112 # 04 Y:2013 | 04 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,800 | $5,850 | Not Implemented |
DL0112 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,034 | $13,739 | Implemented |