Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,289
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AT0061 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,037 | $2,585 | Implemented |
AT0061 # 02 Y:1986 | 02 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $97 | $50 | Implemented |
AT0061 # 03 Y:1986 | 03 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $273 | $500 | Not Implemented |
AT0063 # 01 Y:1987 | 01 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,207 | $5,000 | Implemented |
AT0063 # 02 Y:1987 | 02 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,078 | $500 | Not Implemented |
AT0063 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,247 | $3,793 | Implemented |
AT0063 # 04 Y:1987 | 04 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $716 | $300 | Implemented |
AT0063 # 05 Y:1987 | 05 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $763 | $500 | Implemented |
AT0063 # 06 Y:1987 | 06 | 1987 | INSTALL AUTOMATIC STACK DAMPER | $346 | $800 | Not Implemented |
AT0063 # 07 Y:1987 | 07 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $103 | $195 | Implemented |
AT0063 # 08 Y:1987 | 08 | 1987 | UPGRADE OBSOLETE EQUIPMENT | $200 | $0 | Implemented |
AT0063 # 09 Y:1987 | 09 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $117 | $0 | Not Implemented |
AT0063 # 10 Y:1987 | 10 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $117 | $200 | Implemented |
AT0063 # 11 Y:1987 | 11 | 1987 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $100 | $0 | Implemented |
AT0064 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $107 | $108 | Implemented |
AT0064 # 02 Y:1987 | 02 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $303 | $500 | Implemented |
AT0064 # 03 Y:1987 | 03 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,391 | $3,000 | Not Implemented |
AT0064 # 04 Y:1987 | 04 | 1987 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,374 | $4,200 | Not Implemented |
AT0065 # 01 Y:1987 | 01 | 1987 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,589 | $3,000 | Not Implemented |
AT0065 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,448 | $10,000 | Implemented |
AT0065 # 03 Y:1987 | 03 | 1987 | REDESIGN PROCESS | $2,779 | $6,000 | Not Implemented |
AT0065 # 04 Y:1987 | 04 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $26,038 | $4,000 | Not Implemented |
AT0065 # 05 Y:1987 | 05 | 1987 | IMPROVE LUBRICATION PRACTICES | $4,191 | $0 | Not Implemented |
AT0065 # 06 Y:1987 | 06 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,960 | $1,685 | Not Implemented |
AT0065 # 07 Y:1987 | 07 | 1987 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,196 | $1,800 | Not Implemented |