IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,754

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0156 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,728 $14,629 Not Implemented
OK0156 # 04 Y:1985 04 1985 RECOVER AND REUSE COOLING WATER $1,387 $500 Implemented
OK0156 # 05 Y:1985 05 1985 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,307 $624 Implemented
OK0156 # 06 Y:1985 06 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $9,735 $0 Not Implemented
OK0156 # 07 Y:1985 07 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,633 $531 Not Implemented
OK0156 # 08 Y:1985 08 1985 INSULATE BARE EQUIPMENT $300 $329 Not Implemented
OK0156 # 09 Y:1985 09 1985 INSTALL TIMERS AND/OR THERMOSTATS $1,230 $300 Not Implemented
OK0156 # 10 Y:1985 10 1985 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,411 $0 Implemented
OK0156 # 11 Y:1985 11 1985 INSULATE BARE EQUIPMENT $290 $880 Implemented
OK0156 # 12 Y:1985 12 1985 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $11,431 $0 Not Implemented
OK0151 # 01 Y:1984 01 1984 INSTALL TIMERS AND/OR THERMOSTATS $4,492 $1,100 Implemented
OK0151 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $58 $48 Implemented
OK0151 # 03 Y:1984 03 1984 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $141 $336 Implemented
OK0151 # 04 Y:1984 04 1984 AIR CONDITION ONLY SPACE NECESSARY $334 $0 Implemented
OK0151 # 05 Y:1984 05 1984 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $984 $0 Not Implemented
OK0152 # 01 Y:1984 01 1984 INSTALL TIMERS AND/OR THERMOSTATS $146 $250 Not Implemented
OK0152 # 02 Y:1984 02 1984 RECOVER WASTE HEAT FROM EQUIPMENT $196 $530 Implemented
OK0152 # 03 Y:1984 03 1984 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY $292 $480 Implemented
OK0152 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $292 $134 Implemented
OK0152 # 05 Y:1984 05 1984 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $204 $0 Implemented
OK0152 # 06 Y:1984 06 1984 INSTALL SET-BACK TIMERS $409 $0 Not Implemented
OK0152 # 07 Y:1984 07 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $117 $124 Implemented
OK0152 # 08 Y:1984 08 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $58 $58 Implemented
OK0147 # 01 Y:1984 01 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,160 $900 Implemented
OK0147 # 02 Y:1984 02 1984 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $509 $131 Implemented