Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
168
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0444 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $31,107 | $30 | Implemented |
LE0443 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61,512 | $97,637 | Implemented |
LE0443 # 03 Y:2017 | 03 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,156 | $8,000 | Not Implemented |
LE0443 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,572 | $108,715 | Implemented |
LE0443 # 07 Y:2017 | 07 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,458 | $8,500 | Not Implemented |
LE0443 # 08 Y:2017 | 08 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,903 | $9,500 | Not Implemented |
LE0443 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,710 | $37,500 | Not Implemented |
LE0443 # 11 Y:2017 | 11 | 2017 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $8,886 | $32,000 | Not Implemented |
LE0443 # 12 Y:2017 | 12 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $14,690 | $63,000 | Implemented |
LE0443 # 13 Y:2017 | 13 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,256 | $10,938 | Implemented |
LE0443 # 14 Y:2017 | 14 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,524 | $32,000 | Implemented |
LE0443 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,762 | $1,000 | Implemented |
LE0443 # 04 Y:2017 | 04 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,373 | $5,300 | Not Implemented |
LE0443 # 10 Y:2017 | 10 | 2017 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $385,040 | $1,360,000 | Not Implemented |
LE0443 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,930 | $8,000 | Not Implemented |
WV0552 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,201 | $10,486 | Implemented |
WV0552 # 05 Y:2017 | 05 | 2017 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $9,424 | $1,000 | Implemented |
WV0552 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,913 | $3,240 | Implemented |
WV0552 # 02 Y:2017 | 02 | 2017 | USE POWER DURING OFF-PEAK PERIODS | $17,322 | $2,500 | Implemented |
WV0552 # 03 Y:2017 | 03 | 2017 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $14,015 | $46,500 | Not Implemented |
WV0552 # 04 Y:2017 | 04 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $13,726 | $620 | Not Implemented |
WV0552 # 01 Y:2017 | 01 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $108,472 | $401,920 | Not Implemented |
LE0442 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,763 | $2,250 | Not Implemented |
LE0442 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,887 | $7,663 | Implemented |
LE0442 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,108 | $5,000 | Not Implemented |