Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0147 # 03 Y:1984 | 03 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,650 | $6,252 | Implemented |
OK0147 # 04 Y:1984 | 04 | 1984 | HEAT WATER WITH EXHAUST HEAT | $7,174 | $6,955 | Not Implemented |
OK0147 # 05 Y:1984 | 05 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,120 | $1,236 | Implemented |
OK0147 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $566 | $333 | Implemented |
OK0147 # 07 Y:1984 | 07 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,671 | $1,647 | Implemented |
OK0147 # 08 Y:1984 | 08 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,036 | $720 | Implemented |
OK0147 # 09 Y:1984 | 09 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $492 | $291 | Implemented |
OK0147 # 10 Y:1984 | 10 | 1984 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,362 | $1,090 | Implemented |
OK0149 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $363 | $650 | Implemented |
OK0149 # 02 Y:1984 | 02 | 1984 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,221 | $2,000 | Not Implemented |
OK0149 # 03 Y:1984 | 03 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $351 | $220 | Implemented |
OK0149 # 04 Y:1984 | 04 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $625 | $1,700 | Implemented |
OK0149 # 05 Y:1984 | 05 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $360 | $104 | Implemented |
OK0149 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,556 | $785 | Implemented |
OK0149 # 07 Y:1984 | 07 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $126 | $235 | Implemented |
OK0149 # 08 Y:1984 | 08 | 1984 | INSULATE BARE EQUIPMENT | $155 | $235 | Implemented |
OK0149 # 09 Y:1984 | 09 | 1984 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $826 | $0 | Implemented |
OK0149 # 10 Y:1984 | 10 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,537 | $480 | Implemented |
OK0150 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $320 | $450 | Not Implemented |
OK0150 # 02 Y:1984 | 02 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $140 | $0 | Implemented |
OK0150 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45 | $60 | Implemented |
OK0150 # 04 Y:1984 | 04 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $1,250 | $180 | Implemented |
OK0150 # 05 Y:1984 | 05 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $745 | $122 | Not Implemented |
OK0150 # 06 Y:1984 | 06 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,460 | $1,350 | Not Implemented |
OK0150 # 07 Y:1984 | 07 | 1984 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $60 | $50 | Implemented |