Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0632 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,410 | $37,900 | Implemented |
GT0632 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $205 | $130 | Not Implemented |
GT0632 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $779 | $975 | Not Implemented |
GT0632 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $571 | $3,150 | Not Implemented |
GT0632 # 05 Y:1998 | 05 | 1998 | INSTALL OCCUPANCY SENSORS | $1,890 | $680 | Not Implemented |
GT0632 # 06 Y:1998 | 06 | 1998 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $740 | $75 | Implemented |
GT0632 # 07 Y:1998 | 07 | 1998 | METER WASTE WATER | $770 | $300 | Not Implemented |
GT0632 # 08 Y:1998 | 08 | 1998 | REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE | $3,191 | $15,160 | Not Implemented |
GT0632 # 09 Y:1998 | 09 | 1998 | ADD ADDITIONAL PRODUCTION SHIFT | $628,800 | $0 | Implemented |
SD0190 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,869 | $11,580 | Implemented |
SD0190 # 02 Y:1998 | 02 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $30,174 | $15,667 | Not Implemented |
SD0190 # 03 Y:1998 | 03 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,878 | $116,225 | Not Implemented |
SD0190 # 04 Y:1998 | 04 | 1998 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $17,334 | $8,125 | Not Implemented |
SD0190 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,620 | $1,350 | Implemented |
SD0190 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,072 | $0 | Implemented |
SD0190 # 07 Y:1998 | 07 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $788 | $300 | Not Implemented |
SD0190 # 08 Y:1998 | 08 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,086 | $4,856 | Not Implemented |
SD0190 # 09 Y:1998 | 09 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,443 | $6,942 | Implemented |
SD0190 # 10 Y:1998 | 10 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,302 | $2,150 | Implemented |
SD0190 # 11 Y:1998 | 11 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,500 | $9,000 | Implemented |
SD0190 # 12 Y:1998 | 12 | 1998 | RECYCLE WHITE WATER | $445 | $0 | Not Implemented |
SD0190 # 13 Y:1998 | 13 | 1998 | MODIFY CURRENT INCENTIVE PROGRAM | $226,039 | $560,000 | Not Implemented |
SF0133 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,167 | $156 | Implemented |
SF0133 # 02 Y:1998 | 02 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $878 | $0 | Not Implemented |
SF0133 # 03 Y:1998 | 03 | 1998 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,152 | $1,611 | Implemented |