Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,576
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0408 # 07 Y:2002 | 07 | 2002 | PAY BILLS ON TIME TO AVOID LATE FEES | $788 | $0 | Implemented |
AM0408 # 08 Y:2002 | 08 | 2002 | INSULATE BARE EQUIPMENT | $500 | $600 | Implemented |
AM0408 # 09 Y:2002 | 09 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $368 | $145 | Not Implemented |
AM0407 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,330 | $300 | Implemented |
AM0407 # 02 Y:2002 | 02 | 2002 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $920 | $699 | Not Implemented |
AM0407 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $690 | $210 | Not Implemented |
AM0407 # 04 Y:2002 | 04 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $190 | $0 | Implemented |
AM0407 # 05 Y:2002 | 05 | 2002 | REUSE RAGS UNTIL COMPLETELY SOILED | $180 | $0 | Implemented |
TA0021 # 01 Y:2002 | 01 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,450 | $5,883 | Implemented |
TA0021 # 02 Y:2002 | 02 | 2002 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,736 | $19,010 | Not Implemented |
TA0021 # 03 Y:2002 | 03 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $6,110 | $190 | Implemented |
TA0021 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $864 | $504 | Implemented |
TA0021 # 05 Y:2002 | 05 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $535 | $0 | Implemented |
TA0021 # 06 Y:2002 | 06 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $103 | $0 | Implemented |
AM0406 # 01 Y:2002 | 01 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,400 | $1,600 | Implemented |
AM0406 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,975 | $2,250 | Implemented |
AM0406 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,460 | $200 | Implemented |
AM0406 # 04 Y:2002 | 04 | 2002 | USE A RAG RECYCLE SERVICE | $830 | $0 | Implemented |
AM0406 # 05 Y:2002 | 05 | 2002 | REUSE RAGS UNTIL COMPLETELY SOILED | $830 | $0 | Implemented |
AM0406 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $520 | $320 | Implemented |
AM0406 # 07 Y:2002 | 07 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $450 | $1,035 | Implemented |
AM0405 # 01 Y:2002 | 01 | 2002 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $74,250 | $400,000 | n/a |
AM0405 # 02 Y:2002 | 02 | 2002 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $52,500 | $0 | Not Implemented |
AM0405 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $7,300 | $700 | Not Implemented |
AM0405 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,330 | $400 | Implemented |