Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,059
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0145 # 03 Y:2019 | 03 | 2019 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $7,173 | $2,200 | Not Implemented |
WM0145 # 04 Y:2019 | 04 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,925 | $2,210 | Not Implemented |
WM0145 # 05 Y:2019 | 05 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,800 | $1,040 | Not Implemented |
WM0145 # 06 Y:2019 | 06 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,032 | $771 | Not Implemented |
WM0145 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,002 | $3,768 | Implemented |
WM0145 # 08 Y:2019 | 08 | 2019 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $1,134 | $0 | Not Implemented |
WM0143 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,945 | $12,879 | Not Implemented |
WM0143 # 02 Y:2019 | 02 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,367 | $6,400 | Not Implemented |
WM0143 # 03 Y:2019 | 03 | 2019 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,586 | $0 | Not Implemented |
WM0143 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,884 | $4,500 | Implemented |
WM0143 # 05 Y:2019 | 05 | 2019 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $3,255 | $0 | Not Implemented |
WM0143 # 06 Y:2019 | 06 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,250 | $0 | Not Implemented |
WM0143 # 07 Y:2019 | 07 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,164 | $1,500 | Not Implemented |
WM0143 # 08 Y:2019 | 08 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,815 | $2,460 | Not Implemented |
WM0143 # 09 Y:2019 | 09 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,598 | $2,000 | Not Implemented |
WM0143 # 10 Y:2019 | 10 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,438 | $928 | Not Implemented |
WM0143 # 11 Y:2019 | 11 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,240 | $748 | Not Implemented |
WM0143 # 12 Y:2019 | 12 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $979 | $0 | Not Implemented |
WM0142 # 01 Y:2019 | 01 | 2019 | INSTALL OCCUPANCY SENSORS | $19,750 | $28,500 | Not Implemented |
WM0142 # 02 Y:2019 | 02 | 2019 | USE RADIANT HEATER FOR SPOT HEATING | $7,329 | $9,450 | Implemented |
WM0142 # 03 Y:2019 | 03 | 2019 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,679 | $6,540 | Implemented |
WM0142 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,469 | $3,500 | Implemented |
WM0142 # 05 Y:2019 | 05 | 2019 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,795 | $2,700 | Implemented |
WM0142 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $619 | $1,160 | Implemented |
WM0142 # 07 Y:2019 | 07 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $418 | $750 | Not Implemented |