Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,996
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0161 # 06 Y:1997 | 06 | 1997 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,460 | $900 | Not Implemented |
SD0161 # 07 Y:1997 | 07 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,573 | $1,800 | Not Implemented |
SD0161 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $965 | $2,700 | Implemented |
SD0161 # 09 Y:1997 | 09 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,614 | $10,360 | Implemented |
SD0161 # 10 Y:1997 | 10 | 1997 | INSTALL OCCUPANCY SENSORS | $1,963 | $820 | Implemented |
SD0161 # 11 Y:1997 | 11 | 1997 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $496 | $0 | Implemented |
SD0161 # 12 Y:1997 | 12 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $14,696 | $9,000 | Implemented |
SD0161 # 13 Y:1997 | 13 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $33,136 | $8,000 | Not Implemented |
SD0161 # 14 Y:1997 | 14 | 1997 | CLEAR AND RENT EXISTING SPACE | $23,046 | $152 | Implemented |
SD0161 # 15 Y:1997 | 15 | 1997 | CONDENSE OPERATION INTO ONE BUILDING | $48,384 | $0 | Implemented |
AM0289 # 01 Y:1997 | 01 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $21,800 | $5,500 | Implemented |
AM0289 # 02 Y:1997 | 02 | 1997 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,830 | $1,050 | Implemented |
AM0289 # 03 Y:1997 | 03 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,330 | $0 | Implemented |
AM0289 # 04 Y:1997 | 04 | 1997 | BURN WASTE OIL FOR HEAT | $820 | $0 | Implemented |
AM0289 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $650 | $50 | Implemented |
AM0289 # 06 Y:1997 | 06 | 1997 | PAY UTILITY BILLS ON TIME | $600 | $0 | Implemented |
AM0289 # 07 Y:1997 | 07 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $440 | $0 | Implemented |
AM0289 # 08 Y:1997 | 08 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $230 | $100 | Implemented |
AM0289 # 09 Y:1997 | 09 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $170 | $0 | Implemented |
AM0288 # 01 Y:1997 | 01 | 1997 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $2,220 | $0 | Implemented |
AM0288 # 02 Y:1997 | 02 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,380 | $10,440 | Not Implemented |
AM0288 # 03 Y:1997 | 03 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $1,580 | $430 | Implemented |
AM0288 # 04 Y:1997 | 04 | 1997 | INSTALL SKYLIGHTS | $900 | $2,700 | Not Implemented |
AM0288 # 05 Y:1997 | 05 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,200 | $150 | Implemented |
AM0288 # 06 Y:1997 | 06 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,197 | $800 | Implemented |