IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,150

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0090 # 05 Y:1983 05 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $795 $152 Not Implemented
KU0090 # 06 Y:1983 06 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $591 $20 Not Implemented
KU0090 # 07 Y:1983 07 1983 INSTALL AUTOMATIC STACK DAMPER $476 $825 Implemented
KU0090 # 08 Y:1983 08 1983 INSTALL AUTOMATIC STACK DAMPER $164 $375 Not Implemented
KU0091 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,478 $912 Not Implemented
KU0091 # 02 Y:1983 02 1983 INSTALL TIMERS AND/OR THERMOSTATS $1,331 $400 Not Implemented
KU0091 # 03 Y:1983 03 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $461 $522 Not Implemented
KU0091 # 04 Y:1983 04 1983 INSTALL AUTOMATIC STACK DAMPER $300 $300 Not Implemented
KU0091 # 05 Y:1983 05 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $223 $90 Not Implemented
UD0089 # 01 Y:1983 01 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $5,685 $7,000 Not Implemented
UD0089 # 02 Y:1983 02 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $12,879 $30,000 Implemented
UD0089 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,029 $408 Not Implemented
OK0087 # 01 Y:1983 01 1983 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $118 $120 Not Implemented
OK0087 # 02 Y:1983 02 1983 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $42 $0 Not Implemented
OK0087 # 03 Y:1983 03 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,133 $250 Implemented
OK0087 # 04 Y:1983 04 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,062 $3,740 Not Implemented
OK0087 # 05 Y:1983 05 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $942 $4,420 Not Implemented
OK0087 # 06 Y:1983 06 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $769 $757 Not Implemented
OK0087 # 07 Y:1983 07 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $210 $13 Not Implemented
OK0087 # 08 Y:1983 08 1983 INSTALL TIMERS AND/OR THERMOSTATS $114 $326 Not Implemented
OK0096 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $297 $318 Implemented
OK0096 # 02 Y:1983 02 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $865 $0 Not Implemented
OK0096 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $2,949 $725 Implemented
OK0096 # 04 Y:1983 04 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,615 $600 Not Implemented
OK0096 # 05 Y:1983 05 1983 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $184 $785 Not Implemented