Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,911
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0388 # 07 Y:2015 | 07 | 2015 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,735 | $9,703 | Not Implemented |
LE0388 # 08 Y:2015 | 08 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $272 | $1,200 | Implemented |
DL0138 # 01 Y:2015 | 01 | 2015 | INSULATE BARE EQUIPMENT | $165,235 | $79,620 | Not Implemented |
DL0138 # 02 Y:2015 | 02 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $81,150 | $0 | Implemented |
DL0138 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $65,410 | $20,000 | Implemented |
DL0138 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,355 | $7,475 | Not Implemented |
DL0138 # 05 Y:2015 | 05 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,660 | $19,415 | Not Implemented |
DL0138 # 06 Y:2015 | 06 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,465 | $650 | Not Implemented |
DL0138 # 07 Y:2015 | 07 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,870 | $1,700 | Not Implemented |
DL0138 # 08 Y:2015 | 08 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,480 | $0 | Not Implemented |
DL0138 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,280 | $61,980 | Implemented |
DL0138 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,645 | $13,720 | Implemented |
DL0138 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,660 | $21,550 | Implemented |
DL0138 # 12 Y:2015 | 12 | 2015 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,315 | $0 | Not Implemented |
LE0387 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $1,375 | $0 | Not Implemented |
LE0387 # 02 Y:2015 | 02 | 2015 | ADJUST VENTS TO MINIMIZE ENERGY USE | $163,566 | $7,716 | Not Implemented |
LE0387 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,549 | $1,000 | Not Implemented |
LE0387 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $67,292 | $22,580 | Not Implemented |
LE0387 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,707 | $2,050 | Not Implemented |
LE0387 # 06 Y:2015 | 06 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $83,193 | $86,300 | Not Implemented |
LE0387 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,929 | $14,175 | Not Implemented |
LE0387 # 08 Y:2015 | 08 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,919 | $23,100 | Not Implemented |
LE0382 # 01 Y:2014 | 01 | 2014 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $11,599 | $0 | Implemented |
LE0382 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $555 | $0 | Implemented |
LE0382 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,119 | $0 | Implemented |