Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,102
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0660 # 04 Y:2024 | 04 | 2024 | INSTALL OCCUPANCY SENSORS | $7,224 | $4,470 | n/a |
SD0660 # 05 Y:2024 | 05 | 2024 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $1,431,356 | $2,700 | n/a |
SD0660 # 06 Y:2024 | 06 | 2024 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $39,277 | $137,300 | n/a |
SD0660 # 07 Y:2024 | 07 | 2024 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $2,963 | $0 | n/a |
AS0586 # 01 Y:2024 | 01 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $43,149 | $275,575 | n/a |
AS0586 # 02 Y:2024 | 02 | 2024 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,551 | $7,200 | n/a |
AS0586 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $11,286 | $5,605 | n/a |
AS0586 # 04 Y:2024 | 04 | 2024 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,163 | $499 | n/a |
AS0586 # 05 Y:2024 | 05 | 2024 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $9,160 | $4,152 | n/a |
AS0586 # 06 Y:2024 | 06 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,346 | $1,441 | n/a |
AS0586 # 07 Y:2024 | 07 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $787 | $3,178 | n/a |
AS0587 # 01 Y:2024 | 01 | 2024 | COMBINE UTILITY METERS | $30,741 | $605 | n/a |
AS0587 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $23,057 | $176,288 | n/a |
AS0587 # 03 Y:2024 | 03 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $17,501 | $95,089 | n/a |
AS0587 # 04 Y:2024 | 04 | 2024 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $13,232 | $5,780 | n/a |
AS0587 # 05 Y:2024 | 05 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $10,418 | $95,089 | n/a |
AS0587 # 06 Y:2024 | 06 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,127 | $21,892 | n/a |
AS0587 # 07 Y:2024 | 07 | 2024 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,422 | $0 | n/a |
AS0587 # 08 Y:2024 | 08 | 2024 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $3,680 | $136 | n/a |
AS0587 # 09 Y:2024 | 09 | 2024 | INSTALL OCCUPANCY SENSORS | $1,326 | $2,077 | n/a |
MZ0365 # 01 Y:2024 | 01 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,949 | $1,000 | n/a |
MZ0365 # 02 Y:2024 | 02 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,558 | $75,320 | n/a |
MZ0365 # 03 Y:2024 | 03 | 2024 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,741 | $805 | n/a |
MZ0365 # 04 Y:2024 | 04 | 2024 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $96 | $520 | n/a |
MZ0365 # 05 Y:2024 | 05 | 2024 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $267,134 | $875,396 | n/a |